Instruction manual
Wiring and Device Connections
31
Enova DVX-2150HD/2155HD All-in-One Presentation Switcher Operation/Reference Guide
To use the 4-pin 3.5 mm mini-Phoenix (female) captive-wire connector for data communication and power transfer, the
incoming PWR and GND cable from the 12 VDC-compliant power supply must be connected to the AxLink cable
connector going to the DVX. FIG. 49 shows the wiring diagram.
Make sure to connect only the GND wire on the AxLink/PWR connector when using a separate 12 VDC power supply.
Do not connect the PWR wire to the AxLink connector’s PWR (+) opening.
Power Connector/Switch/Fuse
FIG. 50 displays the power switch and connector for the DVX.
FIG. 49 4-pin mini-Phoenix connector wiring diagram (using external power source)
Top view
Top view
To the Controller’s
AxLink/PWR connector
To the external AxLink device
Local 12+ VDC
power supply
(coming from an
external
power supply)
When you connect an external power supply, do not connect the wire from the PWR
terminal (coming from the external device) to the PWR terminal on the Phoenix
connector attached to the Controller unit. Make sure to connect only the AXM, AXP,
and GND wires to the Controller’s Phoenix connector when using an external power
supply.
FIG. 50 Power Connector/Switch/Fuse
Power switch
Fuse (250V, 2.5A)
Power cable connector
This unit should only have one source of incoming power.
Using more than one source of power to the Controller can result in damage to the
internal components and a possible burn out.
Apply power to the unit only after installation is complete.