Instruction manual
Wiring and Device Connections
30
Enova DVX-2150HD/2155HD All-in-One Presentation Switcher Operation/Reference Guide
AxLink Port and LED (4-pin captive-wire)
The AxLink port (FIG. 47) allows the DVX to support AMX AxLink devices.
The (green) AxLink LED indicates AxLink data activity:
Off - No power, or the controller is not functioning properly.
1 blink per second - Normal operation.
3 blinks per second - AxLink bus error. Check all AxLink bus connections.
The AxLink port can be used to supply power to downstream AxLink-compatible devices as long as the maximum
current draw is less than 1 Amp. To isolate the DVX from high inrush current, AxLink devices, or potential power faults
on the AxLink bus, it is strongly recommended that you power external AxLink devices from an independent power
supply.
Refer to the following table for the wiring length information used with the DVX:
FIG. 48 provide wiring requirements for the AxLink connector:
FIG. 47 AxLink Port and LED
The AxLink port provides only limited power to connected AxLink devices. It is
recommended to use an alternate power source when connecting AxLink devices to
the DVX-2150HD-SP.
When using the DVX with the NXA-PDU-1508-8 power distribution unit, do NOT
connect +12V power from any of the NXA-PDU's AxLink ports to the AxLink power
pin.
Wiring Guidelines
Wire size Maximum wiring length
18 AWG 154.83 feet (47.19 meters)
20 AWG 98.30 feet (29.96 meters)
22 AWG 63.40 feet (19.32 meters)
24 AWG 38.68 feet (11.79 meters)
FIG. 48
Mini-Phoenix connector wiring diagram (direct data and power)
Top view
Top view
To the Controller’s
AxLink/PWR connector
To the external AxLink device