Enova DVX-2150HD/2155HD All-in-One Presentation Switcher Operation/Reference Guide
Mounting the DVX into an Equipment Rack
The DVX occupies three rack units in a standard equipment rack. The following steps apply to mounting the DVX:
1. Discharge any static electricity from your body by touching a grounded metal object.
2. Position and install the mounting brackets, as shown in FIG. 2, using the supplied mounting screws.
FIG. 2 displays how the brackets should be attached to the DVX:
3. Install the DVX in the mounting rack by using the mounting screws to affix the unit to the rack.
4. Connect any applicable wires to the DVX. Refer to the Wiring and Device Connections section on page 7 for wiring
diagrams and pinout descriptions. Connect the unit only to a properly-rated supply circuit.
Ventilation
ALWAYS ensure that the rack enclosure is adequately ventilated. Do not block any ventilation openings. Sufficient
airflow must be achieved (by convection or forced-air cooling) to satisfy the ventilation requirements of all the items of
equipment installed within the rack.
The left and right mounting brackets are not identical. Please install in the orientation
shown.
FIG. 2 Rack mounting the DVX-2150HD-SP
DO NOT stand other units directly on top of the DVX when it is rack mounted, as this
will place excessive strain on the mounting brackets.
The maximum operating ambient temperature is 40°C (104°F).
When installing equipment into a rack, distribute the units evenly. Otherwise,
hazardous conditions may be created by an uneven weight distribution.
Reliable earthing (grounding) of rack-mounted equipment should be maintained.
The DVX should not be installed in enclosed spaces. It is recommended that you
leave 1 RU of space above the DVX when you install it in a rack.