User Guide

Programming i!-MacroManager
13
i
!-MacroManager
i!-MacroExecuteMod requires the following touch panel pop-up page:
Programming i!-MacroSchedulerEngineMod
i!-MacroSchedulerEngineMod appears on the NetLinx bus as a NetLinx device. This device has 1
port with channels, levels, commands and strings like most other devices.
Channels
i!-MacroSchedulerEngineMod supports the following channels:
Levels
i!-MacroSchedulerEngineMod supports the following levels:
Commands
i!-MacroSchedulerEngineMod supports the following out-bound commands (master to device):
Popup Page Popup Group
mmMacroBrowse N/A
Channel Description
250 Enable debugging
Channel Description
1-8 Unused
9 Total Event Slots
10 Available Slots
11 Next free Event index
12 Unused
13 Next Event to start
14 Next Event to stop
15 Total Events today
16 Events completed today
17 Number of current events
18 Events left today
i!-MacroSchedulerEngineMod - Commands
Command Description
'SET EVENT-[Event Number],
[Event Name],[Date String],
[Start Time String],
[End Time String]'
Set the name, date, start and end time of an event. All
parameters are optional.
'GET EVENT-[Event Number]'
Get the name, date, start and end time, next start and end
data and time for event.
'SET NAME-[Event Number],
[Event Name]'
Set the name of an event. If name is an empty string, event
will be deleted.
'GET NAME-[Event Number]'
Get the name of an event.
'SET STIME-[Event Number],
[Time String]'
Set start time for event number. If time string is empty, the
event is set for "No Start Time" (i.e. not scheduled)