Technical information
NetLinx Modules
59
RMS NetLinx Programmer’s Guide
RMSUIMod Module
Commands
Module Definition
Touch Panel Pages
Constants
Commands
RMSUIMod listens for the following commands from the vdvRMSEngine
device.
Module Definition
DEFINE_MODULE 'RMSUIMod' mdlRMSUI(dvRMSEngine,
dvTp,
dvTP_Base,
dvTPWelcome,
dvTPWelcome_Base,
RMS_MEETING_DEFAULT_SUBJECT,
RMS_MEETING_DEFAULT_MESSAGE)
vdvRMSEngine:
A virtual device for communicating to RMSEngineMod
RMSEngineMod module
dvTP:
An array of main touch panel devices implementing RMSUIMod.
Commands and Descriptions
'DFORMAT-DAY/
MONTH'
Set Date format European format: Day/Month/Year
'DFORMAT-MONTH/
DAY'
Set Date format US format: Month/Day/Year
'TFORMAT-12 HOUR'
Set Time format to 12 hour format: [01-12]:[00-59]
[AM,PM]
'TFORMAT-24 HOUR'
Set Time format to 24-hour (military) format:
[00-23]:[00-59]
'DEBUG-ON'
Turn on debug.
'DEBUG-OFF'
Turn off debug. (Default)
'VERSION'
Send version information to master debug port (master
messaging)