Specifications
Network Configuration
11
ICSLan Device Control Boxes
Factory Default Parameters
Factory Default Parameters are the values stored in the unit at the time it leaves the factory. EXB Modules can
be restored the unit to their factory default parameters in several ways:
via the ID Pushbutton (see the Performing a Factory Reset section on page 14)
via the RESET FACTORY telnet command (see page 56)
The factory default parameters are listed below:
Factory Default Parameters
Parameter Value
MAC Address As set in factory
Serial Number As set in factory
Ethernet mode Auto (i.e., speed, duplex, both, auto)
IP Addressing Mode DHCP
IP Address (for static mode) 192.168.1.2
Netmask (for static mode) 255.255.255.0
Gateway (for static mode) 192.168.1.1
DNS1 (for static mode) 192.168.1.1
DNS2 (for static mode) 192.168.1.1
DNS3 (for static mode) 192.168.1.1
DNS Domain amx.com
Hostname Last seven digits of the model-serial number - unique for each unit
Master Connection Mode NDP - See the Master Connection Modes section on page 10 for details.
Master URL (for TCP and UDP
URL modes)
“” (blank)
Master Connection port number
for TCP and UDP URL modes
1319
Friendly-Name “” (blank)
Note: If the Friendly Name is non-blank, both Friendly Name and Location
are concatenated to make NDPSTRING2, otherwise NDPSTRING2 is
generated from the unit’s serial number.
Location “”
Stored MAC address of Master
(used for NDP binding)
00:00:00:00:00:00
ICSP Device Number 0 (receive dynamic device number from Master)
System Number 0
Username for Master Blank (empty string)
A blank username and password implies that no encryption will be used
Password for Master Blank (empty string)
A blank username and password implies that no encryption will be used
Telnet port 23
A value of 0 disables the telnet server. Telnet is enabled by default.
Telnet username Blank (empty string)
A blank username and password implies that the telnet server will not query
for username password
Telnet password Blank (empty string)
CTOF time 5 (0.5 seconds)
CTON time 5 (0.5 seconds)
Baud Data Rate/Format 9600, 8, N, 1