Wiring and Device Connections
34
Enova DVX-315xHD & DVX-215xHD All-in-One Presentation Switchers - Instruction Manual
CONFIG DIP Switch
Use the Configuration DIP switch to set the information used by the PROGRAM Port for communication or to set the
on-board Master to Program Run Disable (PRD) mode.
FIG. 46 displays the CONFIG DIP switch.
FIG. 46 CONFIG DIP switch
Baud Rate Settings
Before programming the on-board Master, make sure the baud rate you set matches the communication parameters set
on both your PC’s COM port and those set through your NetLinx Studio v 3.x.
By default, the baud rate is set to 38,400 (bps).
Program Run Disable (PRD) Mode
You can also use the PROGRAM port’s Configuration DIP switch to set the on-board Master to Program Run Disable
(PRD) mode according to the settings listed in the table below.
PRD mode prevents the NetLinx program stored in the on-board Master from running during the device’s power-up.
This mode should be used if the resident NetLinx program is causing inadvertent communication and/or control
problems.
If necessary, place the on-board Master in PRD mode and cycle power, then use the NetLinx Studio v 3.x program to
resolve the communication and/or control problems with the resident NetLinx program. After doing so, download the
corrected program, reset the configuration DIP switch to normal mode, recycle power, and try again.
To set the CONFIG DIP Switch:
1. Turn off the power switch on the rear of the unit.
2. Set the CONFIG DIP switch (refer to FIG. 46).
3. Turn on the power switch.
Note: Consider equating PRD Mode to a PC’s SAFE Mode setting. With PRD mode, you can continue to power a unit,
update the firmware, and download a new program while circumventing any problems with a currently downloaded
program. You must power cycle the unit after activating/deactivating PRD mode on Program Port DIP switch #1.
Baud Rate Settings on the Configuration DIP Switch
Baud Rate Position 5 Position 6 Position 7 Position 8
9600 bps OFF ON OFF ON
38,400 bps
(default)
OFFONONON
57,600 bps ON OFF OFF OFF
115,200 bps ON ON ON ON
Note: Note the orientation of the Configuration DIP Switch and the ON position label.
DIP switches 2, 3, and 4 must remain in the OFF position at all times.
PRD Mode Settings
PRD Mode Position 1
Normal mode (default) OFF
PRD Mode ON
Switch position 1 sets PRD mode (UP = ON)
Position 1 UP (ON) = PRD mode enabled
Position 1 DOWN (OFF) = Normal (default) mode - PRD mode disabled