Specifications

Chapter 5 Parameters|VFD-B Series
Revision July 2008, BE16, SW V4.08 & V5.00 5-59
Group 5: Multi-step speeds and PLC (Process Logic Control) parameters
05 - 00 1st Step Speed Frequency Unit: 0.01
05 - 01 2nd Step Speed Frequency Unit: 0.01
05 - 02 3rd Step Speed Frequency Unit: 0.01
05 - 03 4th Step Speed Frequency Unit: 0.01
05 - 04 5th Step Speed Frequency Unit: 0.01
05 - 05 6th Step Speed Frequency Unit: 0.01
05 - 06 7th Step Speed Frequency Unit: 0.01
05 - 07 8th Step Speed Frequency Unit: 0.01
05 - 08 9th Step Speed Frequency Unit: 0.01
05 - 09 10th Step Speed Frequency Unit: 0.01
05 - 10 11th Step Speed Frequency Unit: 0.01
05 - 11 12th Step Speed Frequency Unit: 0.01
05 - 12 13th Step Speed Frequency Unit: 0.01
05 - 13 14th Step Speed Frequency Unit: 0.01
05 - 14 15th Step Speed Frequency Unit: 0.01
Factory Setting: 0.00
Settings 0.00 to 400.00 Hz
The Multi-Function Input Terminals (refer to Pr.04-04 to 04-09) are used to select one of the
AC motor drive Multi-step speeds. The speeds (frequencies) are determined by Pr.05-00 to
05-14 as shown above. They are also used in conjunction with Pr.05-15 to 05-31 for PLC
programs.
05 - 15 PLC Mode
Factory Setting: 00
Settings 00 Disable PLC operation
01 Execute one program cycle
02 Continuously execute program cycles
03 Execute one program cycle step by step
04 Continuously execute program cycles step by step
This parameter selects the mode of PLC operation for the AC motor drive. The AC motor drive
will change speeds and directions according to the desired user programming.
This parameter can be applied in the PLC operation of general small machines, food
processing machines and washing equipment.