Specifications
Chapter 5 Parameters|VFD-B Series
5-44 Revision July 2008, BE16, SW V4.08 & V5.00
03 - 10 Desired Frequency Attained 2 Unit: 0.01
Settings
0.00 to 400.00 Hz
Factory Setting: 0.00
If a multi-function output terminal is set to function as Desired Frequency Attained 1 or 2
(Pr.03-00 to Pr.03-03 = 09 or 22), then the output will be activated when the programmed
frequency is attained.
-2Hz
4Hz
2Hz
OFF
OF F
ON
ON
OF F
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
detection
range
Fr equ enc
y
master
frequency
desired
frequency
detection range
dete ction
ran ge
DC br ake time
during stop
Time
waiting time
for
freque ncy
run/s to p
master freq. attained
(output signal)
des ire d fr eq. attaine d
settin g 03 ze ro spee d indica tion
se tting 24 zero sp eed indi cation
out put timing c hart o f m ultip le func ti on ter mi nals
wh en setting to fr equency attain ed or z ero speed indi cation
03 - 05 Analog Output Signal (AFM)
Factory Setting: 00
Settings 00 Analog Frequency Meter (0 to Maximum Output Frequency)
01 Analog Current Meter (0 to 250% of rated AC motor drive current)
02 Output voltage (0 to Pr.01-02)
03 Output frequency command (0 to Maximum Frequency)
04 Output motor speed (0 to the Maximum Frequency)
05 Load power factor (cos90
o
to 0
o
)
This parameter sets the function of the AFM output 0~+10VDC (ACM is common).
03 - 06 Analog Output Gain Unit: 1
Settings 01 to 200% Factory Setting: 100
This parameter sets the voltage range of the analog output signal.