User guide

Table Of Contents
How to Contact Altera Info–3
December 2013 Altera Corporation Cyclone V Hard IP for PCI Express
User Guide
How to Contact Altera
To locate the most up-to-date information about Altera products, refer to the following table.
November 2012 12.1
Added support for Root Ports when using the Avalon-MM Hard IP for PCI Express.
Add support for multiple MSI and MSI-X messages Avalon-MM Hard IP for PCI Express.
Corrected value of AC coupling capacitor in Table 18–1 on page 18–2. The correct value
is 0.1 uF.
Revised Qsys example design to include a separately instantiated Transceiver
Reconfiguration Controller IP Core and a software driver to program the Transceiver
Reconfiguration Controller.
June 2012 12.01
Added Chapter 18, Testbench and Design Example.
Updated Getting started chapters to include steps to simulate using the Root Port and
Endpoint BFMs described in the Testbench and Design Example chapter.
Added Avalon-MM interface support with full-featured and completer-only variants.
Added support for VHDL simulation.
Added support for dynamic reconfiguration of transceiver settings.
Added support for legacy interrupts.
Added
txswing
and
txmargin[2:0]
to the PIPE interface. This interface is available
for simulation only.
Removed
derr_cor_ext_rcv1
signal which is not used.
Removed
currentspeed[1:0]
and
dlup
signals from reset and status interface.
Corrected definition of flow control protocol error.
Corrected definition of
cpl_err[2]
. This signal only applies to non-posted requests.
Updated definition of
app_msi_req
to include the fact that in Root Port mode, the
header bit[127] of
rx_st_data
is set to 1 to indicate that the TLP being forwarded to
the Application Layer was generated in response to an assertion of the
app_msi_request
pin; otherwise, bit[127] is set to 0.
Removed
dlup
signal. Only
dlup_exit
is necessary.
Added
tl_app_int_sts_vec[7:0]
which replaces
app_inta–app_intd
signals.
Corrected explanation of Type 0 and Type 1 Configuration Space TLPs in Root Port
mode in Chapter 13, Flow Control.
Corrected size of RX buffer. It is 6 KBytes.
Removed fixedclk_locked signal.
Changed frequency range for Transceiver Reconfiguration Controller IP Core clock from
90–100 MHz to 100–125 MHz.
Corrected definitions of Avalon-MM to PCI Express interrupt registers in Table 8–25 on
page 8–12 and Table 8–26 on page 8–13.
November 2011 11.1 First release.
Contact
(1)
Contact Method Address
Technical support Website www.altera.com/support
Date Version Changes Made SPR