Specifications
Table Of Contents

D ESIGN C ONSULTING
Electrosonic Systems, Inc. Page 1 of 11
Design Consulting DEC100167 www.electrosonic.com
3320 N. San Fernando Blvd. Beverly Hills City Hall Tel: +1-818-333-3600
Burbank, CA 91504, USA Television Production AVC Systems Upgrade Fax: +1-818-566-4923
Beverly Hills City Hall
Television Production AVC Systems Upgrade
AVC Narrative
October 15
th
, 2012
The City of Beverly Hills requires audio, video and control upgrades to its Television
Production System relating to the Council Chambers, Room A and Control Room. The
general overall scope of work, to be detailed further on in this document is:
Council Chambers:
Replace/upgrade video distribution system from analog to digital.
Provide new digital video matrix
Replace/upgrade audio DSP system
Replace wireless and wired microphone systems
Replace/upgrade AMX control system, touch screens and programming
Replace/upgrade AV networking
A change to the existing SDI broadcast camera system is not in this scope.
Room A:
Remove current AV rack, projector and projection screen.
Provide new AV rack with digital video matrix, audio DSP, wireless microphone
systems control system and networking.
Provide (4) new SDI/HD-SDI remote pan/tilt cameras (will require new AC power drops
in ceiling)
Provide new LED-LCD wall monitors
Replace current ceiling speakers
Replace/upgrade AMX control touch screens and programming
Control Room:
Replace/upgrade analog audio console to digital
Provide new remote camera control unit for new Room A camera system
Provide new audio DSP head end processor
Provide new digital video matrix and connections into existing TV broadcast system
Replace/upgrade control touch screens and programming
Overall Project:
Provide: site meetings, engineered drawings, procurement, fabrication, installation
(including low voltage and high voltage cable/conduit supply and install as required),
test, commissioning, programming, training and warranty for a full turnkey deliverable
to the City of Beverly Hills.
The AV systems in these rooms are currently functional. Some of the existing cabling
shall be re-used for the upgrade – but this is mostly limited to the analog microphone
audio and control cables. The upgrade project shall require some cables to be
removed and replaced with new types. New cable runs shall also be required from the