User Guide

99
Standard NetLinx API (SNAPI) R 1.8.0
Listener Functions: (Cont.)
Name: Channel: Level: Command: Constant: Notes:
processPoolSpaAuxOn-
Event
POOLAUX-<aux number>,<state> Pool/Spa Aux state changed where <aux number> is the number of the aux relay 1 to x
where x is the maximum supported aux relay and <state> is 1 (on) or 0 (off) (see spe-
cific module documentation)
processPoolSpaOut-
doorTemperatureEvent
34 OUTDOOR_TEMP_LVL Outdoor air temperature changed, value is in degrees C or F depending on temperature
scale
processPoolSpaTemper-
atureScaleEvent
POOLSCALE-<scale> Pool temperature scale changed, <scale> is FAHRENHEIT,CELSIUS
processPoolTemperatu-
reEvent
41 POOL_TEMP_LVL Pool temperature changed, value is in degrees C or F depending on temperature scale
processSpaBlowerOn-
Event
186 SPA_BLOWER_FB Feedback Channel: Spa blower is on while channel is active
processSpaHeat-
StateEvent
179 SPA_HEATER_FB Feedback Channel: Spa heater set to heat state, see state chart
processSpaHeat-
StateEvent
178 SPA_HEAT_OFF_FB Feedback Channel: Spa heater set to off state, see state chart
processSpaHeat-
StateEvent
180 SPA_SOLAR_FB Feedback Channel: Spa heater set to solar state, see state chart
processSpaHeat-
StateEvent
181 SPA_SOLAR_PREF_FB Feedback Channel: Spa heater set to solar preferred state, see state chart
processSpaHeatSta-
tusEvent
189 SPA_HEATING Feedback Channel: Spa heater status is heater, see state chart
processSpaHeatSta-
tusEvent
190 SPA_HEATING_SOLAR Feedback Channel: Spa heater status is solar, see state chart
processSpaJetsEvent 185 SPA_JETS_HI_FB Feedback Channel: Spa jets state is high, see state chart
processSpaJetsEvent 183 SPA_JETS_LO_FB Feedback Channel: Spa jets state is low, see state chart
processSpaJetsEvent 184 SPA_JETS_MED_FB Feedback Channel: Spa jets state is medium, see state chart
processSpaJetsEvent 182 SPA_JETS_OFF_FB Feedback Channel: Spa jets state is off, see state chart
processSpaLightOn-
Event
173 SPA_LIGHT_FB Feedback Channel: Spa light is on while channel is active
processSpaPumpOn-
Event
171 SPA_PUMP_FB Feedback Channel: Spa pump is on while channel is active
processSpaSet-
pointEvent
40 SPA_HEAT_LVL Spa setpoint changed, value is in degrees C or F depending on temperature scale
processSpaTemperatu-
reEvent
42 SPA_TEMP_LVL Spa temperature changed, value is in degrees C or F depending on temperature scale