Technical information

07/2013 WDOC3416600XXX www.forestgroup.nl
BCS TUBULAR MOTOR WITH BUILD-IN RECEIVER
AND ELECTRONIC LIMIT SETTING
ADJUSTING UPPER AND LOWER END LIMITS:
IMPORTANT: when more motors are programmed to one channel, end limits of all motors will be
adjusted
press button one time press OPEN button one time press button one time
or or or
or or or
press STOP button when required
motor will turn adjust UP limit height is reached. Press STOP button
to acknowledge 5 times slowly for 1 seconds to confirm
or
or or
press STOP button when required
motor will turn adjust DOWN limit height is reached. Press STOP button
to acknowledge 5 times slowly for 1 seconds to confirm
or or
motor will turn to acknowledge,
limits has been set successfully.
43