Technical information
07/2013 WDOC3416600XXX www.forestgroup.nl
BCS TUBULAR MOTOR - BUILD-IN RECEIVER
AND ELECTRONIC LIMIT SETTING
TECHNICAL SPECIFICATION:
● 3416600099 – 6Nm, 33rpm, build-in receiver, electronic limit setting (110V)
● 3416600110 – 3Nm, 28rpm, build-in receiver, mechanical limit setting (230V)
● 3416600112 – 6Nm, 28rpm, build-in receiver, electronic limit setting (230V)
● 3416600116 – 13Nm, 14rpm, build-in receiver, electronic limit setting (230V)
● 3416600117 – 6Nm, 20rpm, build-in receiver, electronic limit setting, Quiet (230V)
● max. running time 4 min.
● protection degree IP44 (230V), class B (110V)
● has to be used with Multi remote and/or Multi wall switch RF
IMPORTANT
230V: use only wires BROWN (phase), BLUE (neutral) and GREEN/YELLOW (earth).
The additional two wires are for connecting the optional obstruction sensor.
Make sure these two wires do NOT make contact with power or connect together.
110V: use only wires BLACK (phase), WHITE (neutral) and GREEN (earth).
230Vac:
PHASE
NEUTRAL
EARTH
41