Technical information
Shuttle manual input features
The default setting of the manual input of the Shuttle:
- pulse connection between pin 3 and 1 → system OPENS,
- pulse connection between pin 3 and 8 → system CLOSES.
Manual input of the Shuttle can be programmed different with a Shuttle IR programming remote 5201002250
and a Shuttle IR receiver 5201001260:
1) SPST : pulse connection between 3 and 8: OPEN STOP CLOSE STOP
2) STOP on SPDT manual input release (in case when pulse contacts are not available):
- connection between pin 3 and 1 → system OPENS until connection is released,
- connection between pin 3 and 8 → system CLOSE until connection is released.
3) Swap OPEN and CLOSE on SPDT, invert SPST:
Reset manual input features
Note: manual input features are also reset to default setting when the Shuttle is reset to default by means of configuration button on
Shuttle motor.
04/2011 WDOC SHMANINPUT www.forestgroup.nl
26