CONTENT v1.8 1) Forest motorisation in general 1.0) Important instructions for Forest Shuttle 4 1.1) Step by step assembly of the FMS and Shuttle track 5 1.2) Methode of assembling toothed belt 9 2) Shuttle 2.1) Technical information Shuttle 10 2.2) Installation and configuration Shuttle motor 11 2.3) Controlling Shuttle 17 2.3.0) Multi receiver 18 2.3.1) Multi remote 19 2.3.2) Multi wall switch wireless 20 2.3.3) Z-wave remote / receiver 21 2.3.
IMPORTANT INSTRUCTIONS FOREST MOTORISATION Read these instructions carefully before using the Forest Shuttle, FMS and BCS motors and save them for future reference. This Shuttle, FMS and BCS motors is for indoor use ONLY and may not be installed in humid environments such as bathrooms, showers, etc. The Shuttle motor may ONLY be used in combination with the supplied transformer. Do not apply reverse power (wrong polarity) to the Shuttle curtain motor.
STEP BY STEP ASSEMBLY OF THE FMS AND SHUTTLE TRACK Cut the track 10.5cm shorter than the total lenght required. Slide the belt through the track by using the FMS belt connector. Cut the belt under an angle to remove the 1st tooth. This ensures a smooth sliding through the FMS Return Pulley.
STEP BY STEP ASSEMBLY OF THE FMS AND SHUTTLE TRACK Keep one side of the belt flush with the end of the rail. Now start counting 17 teeth of the belt, mark the 17th tooth of the belt and cut it here after. Now connect one end of the belt to the belt connector and insert the first piece of the master carrier into the track. Make sure the first tooth stays outside the connector, in the middle.
STEP BY STEP ASSEMBLY OF THE FMS AND SHUTTLE TRACK Now position the center piece onto the motor pulley, making sure the ball bearing falls into place, and place the top piece on the motor pulley again. Slide the master carrier to the end of the track, against the end pulley. On the side of the motor pulley; mark the first visible tooth on the opposite part of the belt where the first master carrier is attached. Remove the motor pulley again from the track.
STEP BY STEP ASSEMBLY OF THE FMS AND SHUTTLE TRACK Now reposition the end pulley onto the track an fasten the screw. Now tighten all the screws of the motor pulley again. Place the metal FMS clip inside the track, put the motor pulley on the track again and place the metal clip over the motor pulley, to ensure a good fixation.
TECHNICAL INFORMATION SHUTTLE MOTOR SPECIFICATIONS SHUTTLE MOTOR: Maximum torque: Maximum speed: Current draw at max. torque: Operating temperature: Weight per carrier: CE / FCC approved 1,5Nm 100rpm ≈ 15cm/sec 2,7A at 24 Vdc 0-50°C / 32-122°F 1,0kg – max. 10kg/mtr SPECIFICATIONS ADAPTOR: Input: Output: CE / FCC / UL / TÜV Efficiency level V 100-240Vac – max.
15.
WAYS TO OPERATE THE FOREST SHUTTLE RF WIRELESS MULTI TO ADAPTOR Z-WAVE IR WIRELESS SOMFY TO ADAPTOR INFRA RED TO ADAPTOR WIRED MECHANICAL SWITCH TO ADAPTOR HOME AUTOMATION TO ADAPTOR WIRED TO ADAPTOR WIRED POTENTIAL FREE ACTOR FOREST SHUTTLE MULTI RECEIVER CLICK-ON 5201001362 FOREST Z-WAVE MODULE EU: 5201001750 US: 5201001751 SOMFY DRY CONTACT RECEIVER 5104011420 SHUTTLE IR RECEIVER 5201001260 FOREST PULSE WALL SWITCH 5201001900 OR 230Vac FOREST SHUTTLE MULTI RECEIVER 5201001361 BUS SYSTE
FOREST MULTI RECEIVER / WALL SWITCH – 5201001360 / 1 / 2 TECHNICAL SPECIFICATION: ● powered by Shuttle ● can also be used as wall switch ● cable 0,5mtr → 5201001360 ● cable 3,5mtr → 5201001361 ● click-on → 5201001362 ● connect to port 1 of the Forest Shuttle ● can control several Shuttles parallel ● working temperature -10°C - +50°C ● works on Forest Multi Remote and Forest Multi Wall Switch RF program button program button control led open/up button stop button close/down button PROGRAMMING REMOTE / W
FOREST MULTI REMOTE - 5201001460 TECHNICAL SPECIFICATION: ● 3V battery CR2430 ● battery life > 3 years ● frequency 433.92MHz ● transmit power 10mW ● transmit range indoors max.
FOREST MULTI REMOTE - 5201001460 MODE EXPLANATION: Mode manual (man): remote can only be used manually. Timer function is switched off. Mode automatic (auto): timer is switched on, only for the selected channel. Select channel 00 (all channels) to engage on all timers. Mode dynamic ( ): same as automatic mode, open and close time will vary + and – 15 minutes. FEATURES: ● When channel select is set to channel 00, all the channels 1 to 15 will respond to open and close.
Z-WAVE REMOTE / RECEIVER INCLUDING THE SHUTTLE IN A Z-WAVE NETWORK*: select channel press include with pin, green led will light up press button on receiver activate channel press button on receiver press stop to finish EXCLUDING THE SHUTTLE FROM A Z-WAVE NETWORK*: press include/exclude button ~6sec.
SCENE SETTING WITH Z-WAVE REMOTE Scene setting (intermediate positions) on a Shuttle track can only be use in combination with the Forest Z-wave remote. All 3 scenes can be set in the full range between open and close. NOTE: In order to make the scene setting work correctly, make sure that the curtain track is assembled in the way as shown below, to aviod changing the motor direction of the Shuttle. Also make sure the open and close limits are set.
Programming IR channels on Forest Shuttle To program a Forest Shuttle to a different channel you need a 12 channel IR remote control (5201002250). The default setting of the Forest Shuttle is channel 1. To programming a Forest Shuttle put the connector of the IR module in port 1-eye of the Forest Shuttle that you want to program. Remove the IR module from other Forest Shuttles in the same room, otherwise the other Forest Shuttles will be programmed too. Aim the remote control to the IR eye.
SHUTTLE PULSE WALL SWITCH - 5201001900 CONNECTING THE WALLSWITCH Either of the 2 ports (1-EYE or 2-AUX) can be used to connect a (pulse) switch to open, close or stop the drapery. This is called a dry contact connection. Pins 1, 3 and 8 are used for this. If pins 3 (common) and 1 (open) are connected by means of the switch then the drapery will OPEN. If pins 3 (common) and 8 (close) are connected then the drapery will CLOSE.
Building automation wiring diagram for Forest Shuttle For control of a Forest Shuttle by a building automation system an actor is needed. If the building automation system already has relay outputs, then an actor is not needed. The relays output must be dead! (free of potential) Different brands and protocols are possible, in this diagram the basic principle is shown. Used in this diagram is KNX, but can also be AMX, Lutron, Creston etc.
Shuttle manual input features The default setting of the manual input of the Shuttle: - pulse connection between pin 3 and 1 → system OPENS, - pulse connection between pin 3 and 8 → system CLOSES.
POTENTIAL FREE RELAY 5201002230 With this relay 230Vac control signals (for FMS or tubular motor) can be converted to two potential free contacts. These potential free contacts can be used to control Forest Shuttle motors. Control voltage 230Vac Technical specification: Input voltage: 230Vac, 50Hz Output: two potential free contacts Current consumption: 10mA (relay up) Switching power: max. 8A, 250Vac Temp: 0°C - +60°C Terminal: max.
FIXING FMS ONTO FMS TRACK Please see page 3 – 6 for assemly of the track First position the motor sideways onto the motor pulley. Now twist the motor onto the motor pulley so the locking slide is aligned, and push it into the motor pulley. Now the motor is ready for set-up and operation.
TECHNICAL INFORMATION FMS MOTOR SPECIFICATIONS FMS MOTOR: Torque: Speed: Voltages: Operating temperature: Max. runing time: Weight per carrier: CE / FCC / UL approval 0.8 / 1.2Nm / 1.8Nm (30 / 45 / 60Watt) 100rpm ≈ 15cm/sec 110Vac – 60Hz / 230Vac – 50 Hz 0-50°C / 32-122°F 5 minutes 1,0kg – max. 10kg/mtr SPECIFICATIONS TRACK: 20mm Weight: Size: Material: Finish: Available lenghts: 303 gr/mtr (3.25 ounce/ft) 20x20mm (0.79x0.
STEPS TO SET THE LIMITS OF THE FMS MOTOR Preferably set the limits of the motor with the motor in a hanging position. Ensure that the Master Carriers of the system are in the open position, meaning the intended position where you want the master carriers to stop when the curtain is open. • Ensure that the two buttons on the bottom of the motor are visible, by removing the white cap of the motor (2A).
FOREST FMS/BCS MULTI RECEIVER - 5104011500 TECHNICAL SPECIFICATION: ● power 230Vac – 500W ● controls one motor ● can also be used as wall switch ● works on to Forest Multi Remote and Forest Multi Wall Switch RF ● terminal max 2,5mm² ● one channel ● working temperature -10°C - +50°C ● programming identical to Shuttle Multi Receiver program button open/up button stop button close/down button WIRING DIAGRAM: 11/2013 WDOC FMS BCS MULTI RECEIVER www.forestgroup.
FMS/BCS Z-WAVE RECEIVER - 5201001812 FMS TUBULAR MOTOR (BCS) OR switch the brown and black wire (1 and 2) to change the direction of rotation UP/OPEN button DOWN/CLOSE button Technical specification: Frequency: 868MHz Power: 230Vac – 460VA Temp: 0°C - +40°C Terminal: max. 2,5mm² 230Vac: PHASE NEUTRAL EARTH 11/2010 WDOC5201001812 www.forestgroup.
FMS/BCS Z-WAVE RECEIVER - 5201001812 Including a FMS/BCS receiver into a Z-wave controller network: Steps: 1) select channel on the controller by pressing the select button 2) press include/exclude button with a pin, green led on remote will light up 3) press the channel up or down button to activate the channel 4) press 3x quick the UP button on the Z-wave receiver, green led on remote blinks once 5) press stop button on controller, including is completed.
SOMFY RECEIVER FOR FMS / BCS - 5104011410 10/2010 WDOC5201001900 www.forestgroup.
FMS / BCS PULSE WALL SWITCH - 5201001910 FMS TUBULAR MOTOR (BCS) OR Technical specification: Power: 115-230Vac - 10A Temp: 0 - 50°C Terminal: max. 1,5mm² 115-230Vac: PHASE NEUTRAL EARTH 10/2010 WDOC5201001910 www.forestgroup.
Building automation wiring diagram for FMS / BCS For control of a FMS (Forest Motorized System) or BCS (Blind Contract System) by a building automation system an actor is needed. If the home automation system already has relay outputs, then an actor is not needed. Different brands and protocols are possible, in this diagram the basic principle is shown. Used in this diagram is KNX, but can also be AMX, Lutron, Creston etc. Motors have to be connected to earth according to local standards.
MOTOR GROUP RELAY - 5201002240 For electrical decoupling of FMS or tubular motors in parallel connection. The FMS and tubular motors with mechanical limit-switches must as a rule not be electrically connected directly in parallel, because due to the different motor running times the limit-switches of some motors may be reached while other motors are still running.
BLIND CONTRACT SYSTEM Keep in mind: ● the profile must be cut 1,5cm shorter than the total width of the system ● the octogonal tube must be cut 5,5cm shorter than the profile, or 7cm shorter than the total width of the system ● BCS profile lenght is max. 5,80 mtr. ● BCS curtain height is max. 5,50 mtr. ● max.
BLIND CONTRACT SYSTEM Installing the Blind Contract System Use one wall/ceiling bracket for every 50-60cm track length. Mount the system on wall/ceiling and attach the fabric. Attach the snap cord fixers on the cords at the bottom of the blind. Do not cut off the exces cord yet. adjustment screws octogonal tube Setting the motor end positions ● when the track is pre-assembled the cord is fully unwound (closed blind position). The lower end position is already set.
BCS TUBULAR MOTOR - BUILD-IN RECEIVER AND ELECTRONIC LIMIT SETTING TECHNICAL SPECIFICATION: ● 3416600099 – 6Nm, 33rpm, build-in receiver, electronic limit setting (110V) ● 3416600110 – 3Nm, 28rpm, build-in receiver, mechanical limit setting (230V) ● 3416600112 – 6Nm, 28rpm, build-in receiver, electronic limit setting (230V) ● 3416600116 – 13Nm, 14rpm, build-in receiver, electronic limit setting (230V) ● 3416600117 – 6Nm, 20rpm, build-in receiver, electronic limit setting, Quiet (230V) ● max.
BCS TUBULAR MOTOR - BUILD-IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING PROGRAMMING REMOTE / WALL SWITCH TO TUBULAR MOTOR (button presses within 6 seconds) ADD MORE REMOTES / WALL SWITCHES / CHANNELS TO TUBULAR MOTOR (button presses within 6 seconds) first select the desired channel first select the desired channel press button on motor, motor will turn short to acknowledge 1st remote: press button two times CANCEL ALL REMOTES OR WALL SWITCHES (button presses within 6 seconds) press button one time
BCS TUBULAR MOTOR WITH BUILD-IN RECEIVER AND ELECTRONIC LIMIT SETTING ADJUSTING UPPER AND LOWER END LIMITS: IMPORTANT: when more motors are programmed to one channel, end limits of all motors will be adjusted press button one time press OPEN button one time or press button one time or or or or or motor will turn to acknowledge adjust UP limit press STOP button when required height is reached.
BCS TUBULAR MOTOR WITH BUILD-IN RECEIVER AND ELECTRONIC LIMIT SETTING CANCELLATION OF UPPER AND LOWER END LIMITS: IMPORTANT: When cancelling end limits, all motors programmed to that channel will be cancelled press button one time press CLOSE button one time or or or or motor will turn to acknowledge, limits has been set successfully. REVERSE DIRECTION SETTING: When motor is not running, press button on motor for ~ 7 seconds, until motor turns to acknowledge.
OBSTRUCTION SENSOR SET - 3416800000 This product must be installed by a person with professional knowledge. The installer must comply with the current standards and legislation in the country in which the product is being installed. Only possible for 230Vac tubular motor. With this set a BCS motor will stop turning when something is blocking the roman blind. This prevents the cords from getting stuck when lowering the blind.
WAYS TO OPERATE BCS RF WIRELESS MULTI MULTI BUILD-IN WIRED Z-WAVE SOMFY MECHANICAL SWITCH FOREST TUBULAR MOTOR RECEIVER BUILD-IN 3416600110 3416600112 3416600116 CORDED CORDED ACTOR FOREST MULTI FMS/BCS RECEIVER 5104011500 FOREST Z-WAVE MODULE FMS/BCS (EU ONLY) 5201001812 230Vac HOME AUTOMATION 230Vac SOMFY RECEIVER 5104011410 230Vac 230Vac FOREST FMS/BCS PULSE WALL SWITCH 5201001910 230Vac BUS SYSTEM FOREST MULTI REMOTE WHITE 5201001460 BLACK 5201006460 FOREST MULTI REMOTE WHITE 52010014
WARRANTY & RETURN POLICY Forest Shuttle® Motors, BCS® and FMS® Devices. 1. The Forest Shuttle Motor and Control Devices are warranted against defects of components and workmanship for ten (10) years from the date of purchase from the Forest Group Nederland B.V. factory. The BCS and FMS Devices are warranted against defects of components and workmanship for five (5) years from the date of purchase from the Forest Group Nederland B.V. factory. The warranty is applied when only parts of Forest Group B.V.