Instruction manual
Appendix C – Programmer’s Interface for System Diagnostics
46
Instruction Manual – BCS Basic Control Structure Protocol
Verbosity Settings
The verbosity (v) settings (v0, v1, v2, v3) correspond to the level of detail that will be displayed,
with v0 being the lowest level of detail and v3 being the highest level.
Component Identity Settings
Detailed information for a single system component can be specified (if the system supports it) by using
its identity (i) number setting (i1 through i7) in the following table. Minimal information for all
supported components can be specified by using the identity number i0.
Note: For the number of components that individual products support, see “Appendix A – Product
Specific BCS Commands” on page 25.
Default Settings
At system boot, the ~scrv0i1! setting is displayed.
If the verbosity setting is omitted, the verbosity level will be the lowest (v0).
The component setting must be included; otherwise, entering any of the verbosity settings
alone will result in a display equivalent to v0i0.
If both settings are omitted during a query (~scr!), the information displayed will be at the lowest
verbosity level for all components (v0i0) (FIG. 2 on page 45).
Component Identity Number
All Components i0
Enclosure i1
Storage Blocks i2
Communication Interfaces i3
Hardware / Boards i4
VM Configuration i5
Power System i6
System Sensors i7