Technical data

MCSi-70/84 Digital Brushless AC servo drive system - Ref.0707
Function: In emergency stop. If the bus voltage drops or there is a power
outage for the unit in the acceleration, deceleration or
constant power mode, the drive will get into the dynamic
braking sequence. It stops with the emergency ramp until its
speed is zero as long as the mechanical energy stored in the
motor allows it. Therefore, it limits the command acceleration
for stopping the motor. If anytime during the sequence, the
Drive Enable is interrupted, the motor will turn by inertia.
SP65 = 0 cancels this limiting effect.
Valid values: 0.0, ..., 400.0 (rpm)/ms.
Default value: 0.
Function: Determine the value of the deceleration ramp applied to the
velocity command. Setting this parameter with a 0 value
means that no ramps will be applied.
Valid values: 0.0, ..., 400.0 (rpm)/ms.
Default value: 0.
SP65 BASIC, RW EmergencyAcceleration
SP66 BASIC, RW VelocityDecelerationTime
Motor free
Power Off
Drive
Enable
Power Off
Speed
Enable
Motor
Speed
Drive
Enable
Speed
Enable
Motor
Speed
SP60
SP66
SP66
SP60
SV6