Function: This variable reflects the status of the programmable digital
input at pins 11 and 12 of connector X3. The status of this
variable is affected by IP6.
Valid values: 0 and 1.
Default value: 0.
K group. Monitoring
Function: Contains the value of power of the external ballast resistor.
Valid values: 200, ..., 2000 W.
Default value: 200 W.
Function: Contains the value of the energy pulse that can be dissipated
by the external ballast resistor.
Valid values: 200, ..., 2000 J.
Default value: 200 J.
Function: It displays the temperature of the heatsink of the power stage.
Valid values: 0, ..., 200 °C.
Function: Variable internally useful to the system. It measures the
internal load level of the calculation of the i
2
t at the drive in
percentage used over the maximum.
Valid values: 0, ..., 100 %.
Default value: 0 %.
IV10 USER, RO DigitalInputs
KP3 USER, RW ExtBallastPower
KP4 USER, RW ExtBallastEnergyPulse
KV10 USER, RO CoolingTemperature
KV32 USER, RO I
2
tDrive