Technical data

MCSi-58/84 Digital Brushless AC servo drive system - Ref.0707
Function: Determines the analog function assigned to the programma-
ble analog input.
Valid values: 0, ..., 2.
Default value: 0.
Function: Monitors the voltage through the analog input ANALOG
VELOCITY COMMAND INPUT (VEL+ and VEL-) (pins 2 - 1
of X3). It's display is in volts.
Function: Monitors the input voltage through analog input 2 (pins 18 -
17 of X3). It's display is in volts.
Function: Contains the value of the auxiliary analog command (pins 17
and 18 of X3; usually current command) after being affected
by CP10 and CP11. It must never exceed the value of the
maximum current of the unit.
Valid values: - 50.00, ..., + 50.00 Arms.
Default value: 0.
IP17 USER, RW AnalogFunctionSelector
IP17 Function
IV3 as input
to function Nr 
00 --------
01 Func1
02 Func2
IV1 BASIC, RO AnalogInput1
IV2 USER, RO AnalogInput2
IV3 USER, RO CurrentCommandAfterScaling
VEL +
X3.2
VEL
-
X3.1
IV1
16 Bit
X3.18
X3.17
IV2
12 Bit
X3.19
PROG. ANALOG. INPUT
X3.19