Technical data
Digital Brushless AC servo drive system - Ref.0707 MCSi-39/84
Integrated safety
The Safe Disable function (SD) offered by Fagor MCS Innova drives permits
disabling the power output of the drive making sure that the motor torque is
eliminated as a safe situation.
This function is available through the "Drive Enable" section so called in
standard Fagor servo drive systems. Techniques and elements approved to
be used in safety systems have been considered for its design and internal
operation.
Thus, with a conventional drive (without SD), a contactor would have to be
installed to assure a safe disable of the motor. However, using the safety
techniques (implemented in Fagor MCS Innova drives) guarantees the same
or greater safety without having to use external contactors, thus saving
material and room in the electrical cabinet.
The "Drive Enable" pin already available on conventional Fagor drives works
the same way on drives with Safe Disable although it has been implemented
keeping the safety principles and protocols in mind.
For that, a safety relay with guided contacts has been considered so:
The first contact (NA) enables the power inverter and sets the control part
to rest assuring a redundancy when locking up.
The second contact (NC) is used as an external acknowledgement of the
status of the safety relay. This contact is available between pins 41 and 42
of connector X3 located on the face of the module.
6
2
6
BUS DC
Drive Enable
CONTROL
Set point
M
41
42