Technical data

Digital Brushless AC servo drive system - Ref.0707 MCSi-29/84
Power connection. Mains - Drive
The drive voltage supply is single phase and does not require a transformer.
The table below shows the values recommended for the fuses shown in the
previous figure. They are slow general purpose fuses. If they are installed on
the Mains input lines, their maximum currents will depend on the value of the
Mains voltage.
Model Peak current ( Arms ) Fuse (A)
MCSi 07L 6.5 16
MCSi 11L 10.5 16
MCSi 15L 15.0 25
Note: A thermal switch may optionally replace the fuses.
X5
L2
L1
L2
L1
X4
220 V AC
R
S
T
N
380 V AC
CONTROL
POWER INPUT
POWER INPUTS
X5
L2
L1
L2
L1
X4
220 V AC
220 V AC
R
S
T
N
380 V AC
High
Floating
Voltage
CONTROL
POWER INPUT
POWER INPUTS
220 V AC
Autotransformer or
single-phase transformer
Autotransformer or
single-phase transformer
Warning.
Never make this connection because
there is a risk of destroying the module.
k1 power switch
fuses
2x2.5 mm
2
k1 power switch
fuses
2x2.5 mm
2
X5
L2
L1
L2
L1
X4
220 V AC
R
S
T
N
380 V AC
CONTROL
POWER INPUT
POWER INPUTS
X5
L2
L1
L2
L1
X4
220 V AC
220 V AC
R
S
T
N
380 V AC
380 V AC
CONTROL
POWER INPUT
POWER INPUTS
220 V AC
Warning.
Never make this connection because
there is a risk of destroying the module.
k1 power switch k1 power switch
2x2.5 mm
2 2x2.5 mm
2
fuses
fuses