Installation guide

History of the Manual Updates
The updates below refer to the manual for the control panel with program version 4.0.
Date
Program
version
Description of updates
01-2002 4.1
Addition of description of the output type 41– low battery indicator.
Description of the DLOAD.exe program replaced with information on the
DLOAD10 program (for work in WINDOWS environment).
Introduction of changes in the description of service function FS-112 (local
communication).
03-2002 4.1
Table of contents placed at the beginning of the manual.
Figure 11 - an error corrected in connecting DTR signal to contact no. 20.
08-2002 4.2
DTMF (MST-1) control module added – operation of the system via a telephone
possible only when the user is calling the panel (see info on pages: 5, 15, 70).
01-2003 4.3
Panel's reaction for Type 16 zone depends on "PRIORITY" option settings
(monostable action/bistable action) - p. 7.
A new type of zone reaction added in function FS-26: „19 - perimeter” – p. 7.
Control panel main board equipped with a protective circuit with the
grounding terminal (main board version CA10P V4.2 and next) – p. 18.
Extension of installation safety notes (p. 17, 18).
Change of description of power supply connection (p. 27).
New formats of transmission to the monitoring station added in functions FS-
45, FS-46 – p. 53:
- 0E - Contact ID selected codes
- 0F - Contact ID all codes
Event no. 6 (disarming & clearing alarm) removed from functions FS-69 to FS-
80 – the code is recommended not to be programmed or assigned to the
stations – p. 58-59.
A second set of options added in FS-131 function (1-4) – p. 70.
A new function added: FS-133 – p. 71.
An example of battery capacity estimation included (p. 80).
Replacement of the word „lamp” by „LED”.
07-2003 4.7
New zone type added: ‘Entry/Exit Final” (pp. 7, 47).
Information added on the possibility to connect some keypads in parallel
(p. 22).
Option added to program, together with telephone numbers, special DTMF
signals generated in the process of dialing (see FS 4 p. 39).
Text concerning the battery status testing has been altered (p. 19).
New TELIM format of transmission to monitoring station has been added FS
45-46 (p. 53).
Assignment of new events to monitoring stations has been added in functions
FS 67-68 (p. 58).
New function added: FS 125 – testing outputs (p. 68)
3 new options added to function FS 131 (pp. 70-71).
4 new functions FS 134-FS 137 have been added for new types of zone events
and for programming monitoring codes in TELIM format (p. 72).
Description of conditions signaled by the ALARM LED blinking has been
completed (p. 77).