Installation guide
History of the Manual Updates
The updates below refer to the manual for the control panel with program version 4.0.
Date
Program
version
Description of updates
01-2002 4.1
Addition of description of the output type 41– low battery indicator.
Description of the DLOAD.exe program replaced with information on the
DLOAD10 program (for work in WINDOWS environment).
Introduction of changes in the description of service function FS-112 (local
communication).
03-2002 4.1
Table of contents placed at the beginning of the manual.
Figure 11 - an error corrected in connecting DTR signal to contact no. 20.
08-2002 4.2
DTMF (MST-1) control module added – operation of the system via a telephone
possible only when the user is calling the panel (see info on pages: 5, 15, 70).
01-2003 4.3
Panel's reaction for Type 16 zone depends on "PRIORITY" option settings
(monostable action/bistable action) - p. 7.
A new type of zone reaction added in function FS-26: „19 - perimeter” – p. 7.
Control panel main board equipped with a protective circuit with the
grounding terminal (main board version CA10P V4.2 and next) – p. 18.
Extension of installation safety notes (p. 17, 18).
Change of description of power supply connection (p. 27).
New formats of transmission to the monitoring station added in functions FS-
45, FS-46 – p. 53:
- 0E - Contact ID selected codes
- 0F - Contact ID all codes
Event no. 6 (disarming & clearing alarm) removed from functions FS-69 to FS-
80 – the code is recommended not to be programmed or assigned to the
stations – p. 58-59.
A second set of options added in FS-131 function (1-4) – p. 70.
A new function added: FS-133 – p. 71.
An example of battery capacity estimation included (p. 80).
Replacement of the word „lamp” by „LED”.
07-2003 4.7
New zone type added: ‘Entry/Exit Final” (pp. 7, 47).
Information added on the possibility to connect some keypads in parallel
(p. 22).
Option added to program, together with telephone numbers, special DTMF
signals generated in the process of dialing (see FS 4 p. 39).
Text concerning the battery status testing has been altered (p. 19).
New TELIM format of transmission to monitoring station has been added FS
45-46 (p. 53).
Assignment of new events to monitoring stations has been added in functions
FS 67-68 (p. 58).
New function added: FS 125 – testing outputs (p. 68)
3 new options added to function FS 131 (pp. 70-71).
4 new functions FS 134-FS 137 have been added for new types of zone events
and for programming monitoring codes in TELIM format (p. 72).
Description of conditions signaled by the ALARM LED blinking has been
completed (p. 77).