Installation guide
6 Installation Guide CA-10 plus SATEL
TECHNICAL DESCRIPTION OF THE CONTROL PANEL
Zones
In its basic configuration, the CA-10 plus control panel has 10 zones: 8 on the panel
main board and 2 in the keypad. In its full configuration, with four keypads (or an
expander), the panel has 16 zones available. The panel zone inputs can support any
detectors in the configuration NC, NO, EOL, 2EOL/NC, 2EOL/NO. The use of two-
parameter configuration enables the panel to simultaneously control the detector and
its anti-tampering circuit by means of one pair of wires.
The zones (input lines) can perform the following functions in the system:
0 - ENTRY/EXIT ,
the violation of which, when in the armed mode, will start countdown of
the entry delay time and will enable the delay mechanism for “interior delay” type
zones (violation of an “interior delay” zone without prior violation of the "entry/exit"
zone will trigger an alarm immediately). Upon violation, a “zone violation” code is
sent to the station (it is possible to skip sending this message), and, after counting
down the "entry delay time" and triggering the alarm - a “zone alarm” code. The
"entry delay " countdown can be signaled in the keypad. It is possible to define
automatically bypassing zones if no „entry/exit” zone is violated during the exit delay
time”. Because of its additional functions, this zone type cannot be used as a
common zone for several partitions.
1 - DELAY -
when violated in the armed mode, it starts delay countdown, after which an
alarm is triggered. It will not occur if the zone is disarmed before completion of the
delay countdown. Upon violation, a “zone violation” code is sent to the station (it is
possible to skip sending this message), and, after counting down the "entry delay
time" and triggering the alarm - a “zone alarm” code. The delay is not signaled in
the keypads.
2 - INTERIOR DELAY
- when violated in the armed mode after previous violation of the
ENTRY/EXIT zone, it behaves like a DELAY zone. When violated in the armed
mode without previous violation of the ENTRY/EXIT zone, it behaves like an
INSTANT zone.
3 - INSTANT
- when violated in the armed mode, it immediately triggers an alarm and
sends a ”zone alarm” message to the monitoring station.
4 - DAY/NIGHT -
when violated in the armed mode, it behaves like an INSTANT zone,
while when disarmed, it will signal violation in the keypad (unless the signaling is
disabled) and send a “zone violation” code to the station.
5 - COUNTING L1
- when violated in the armed mode, it increases the status of the first
of three violation counters (a „zone violation” code is sent to the station), until the
number of violations specified for that counter is exceeded (programming in FS-7).
Then, the violation triggers an alarm (a „zone alarm” code is sent to the station).
The violation counter is reset after 30 seconds since the first violation. It is possible
to program another counter count-up time
(FS-123). If the preset number of
violations is not reached within this time, there will be no alarm. The "counting L1"
function can be assigned to more than one zone, then violations of those zones will
be summed up. Violation of the counting zone in armed mode can be signaled in
the keypad in the same way as for the DAY/NIGHT zone.
6 - COUNTING L2
- operation identical as for the "counting L1", but changes the status of
the second of the three counters.
7 - COUNTING L3 -
operation identical as for the "counting L1", but changes the status of
the third of the three counters.
8 - 24H AUDIBLE
- armed all the time, irrespective of whether the partition it is assigned
to is armed, or not. Each violation of this zone will trigger alarm on the BURGLARY
alarm type outputs, in the keypad, and will send a “zone alarm” code. It makes
possible to create anti-tampering circuits and panic buttons.
9 - 24H AUXILIARY -
armed all the time, irrespective of whether the partition it is
assigned to is armed, or not. Each violation of this zone will trigger an alarm in the