Installation guide

Appendix B - Signaling 77
Appendix B
States signaled with LEDs
LEDs 1 to 12:
off - zone free (not violated)
on - zone violated
on with a short off period every 2 seconds - anti-tamper circuit violated in
2EOL/NC or 2EOL/NO type zones
fast blinking - zone has triggered an alarm
flashing every 2 seconds - zone anti-tamper circuit has triggered an alarm
slow blinking - zone bypassed
LEDs ALARM, ARMED (PARTITION), TROUBLE :
ALARM blinking - alarm was triggered in the zone (when none of LEDs 1 to 12
is blinking, the alarm cause will be shown by the function "Viewing alarm log". The
alarm may have been caused by a zone not displayed in the partition, or the zone
belonged also to another partition, where alarm was cleared)
When the function „service message after tamper alarm” (FS-131) is active, the
alarm LED is blinking until the message is cleared with a service code.
ARMED blinking - partition exit delay
ARMED on - partition armed
TROUBLE blinking - control panel has detected some troubles
ALARM, ARMED & TROUBLE blinking - control panel signals entering the
user function
ALARM blinking, ARMED & TROUBLE on - control panel performs function
"Viewing alarm log"
TROUBLE blinking, ALARM & ARMED on - control panel performs function
"Viewing trouble log"