Installation guide

72 Additional Functions
which will be sent, occurs in the system, the control panel will start counting the
time again. This feature can be disabled by programming 00,00,00.
The programming consists in entering three two-digit numbers. After confirmation
of all the numbers, the control panel quits the function.
EXAMPLE:
programming of the test code send after two and a half hours since the last transmission
(communication test).
[1][3][3] [#] - call the function,
[0][0] [#] - enter the number of days,
[0][2] [#] - enter the number of hours,
[3][0] [#] - enter the number of minutes of the communication test and quit the function.
FS-134 - programming codes to bypass the control panel zones
The codes programmed with this function are sent after calling the user function 4
and bypassing the control panel zones. The codes are programmed in the same
way as in the function FS-60.
FS-135 - programming codes to unbypass the control panel zones
The codes programmed with this function are sent after calling the user function 4
and unbypassing the control panel zones. The codes are programmed in the
same way as in the function FS-60.
FS-136 – programming of prefix for extension of identifiers in TELIM
transmission format
(Transmission format used in Germany.)
FS-137 - programming codes to be sent to the monitoring station in TELIM
transmission format
(Transmission format used in Germany.)
Restoring Default Settings, Erasing Codes
If it is necessary to restore the default settings, you should enter the service mode
and call the service functions FS 107 (to restore all the default settings, except for
the user access codes) and FS 110 (to restore the partition master codes, the other
codes being erased). Also, the function FS 108 can be performed (in order to erase
the event log contents).
If the service mode is inaccessible (for example, when the control panel stopped
responding to keypad commands because of a programming error, or the service
code has been lost), follow the procedure below:
1. Switch off power supply (emergency and mains).
2. Set a jumper on J19 RESET pins.
3. Switch on mains supply.
4. On hearing a beep in the keypad, remove the jumper from J19 pins
(the 1
st
partition keypad will enter the service mode).
5. Perform function FS 107 (erasing settings).
6. Perform function FS 110 (erasing codes).
7. Exit the service mode or proceed with programming the control
panel.
This procedure can be disabled by software means. Then the access to the service
mode possible after performance of another procedure described in the service
function FS-131, option 1.