Installation guide

70 Additional Functions
Option 1 refers to disabling the hardware access to the service mode. If this
option is selected, it is only possible to enter the service mode by using the service
access code. If the service code is lost, unblocking the control panel will cause
loss of all settings - the panel will return to its default settings, as after calling the
service functions FS 107 and FS-110. To enter the service mode not knowing the
code, do the following:
 switch off power supply (mains and battery),
 short the RESET pins with a jumper,
 switch on power supply,
 wait about 60 seconds (±5 sec.) and remove the jumper,
 enter from keypad the code: [1][2][3][4][5] (the code should be entered
within 15 seconds) and finish by pressing the [#] or [
*
] key.
After these operations, the control panel should return to its default settings and
remain in the service mode.
Option 2 refers to the control panel working together with the MST-1 module,
which enables the panel to be operated via a telephone generating the DTMF
signals. For such an operation to be possible, the option 3 of the first FS-5 set
(„call answer”) must be activated.
Option 3 refers to the control panel dialer and defines the pulse dialing ratio
during pulse dialing of a telephone number. Selecting the option sets its value at
1:1.5. If the option is not selected, the ratio is 1:2.
NOTE: In Poland, the telecommunication standard requires that the pulse
dialing ratio be set at 1:2.
Selecting the option 4 makes the codes entered in one of the partitions be also
accepted in other partitions. The event log records no particular user number - the
number is always 1, and on the event log printout the annotation (USER) is shown
instead of the user number.
The options 5-8 set the partition timer priority during disarming. With this option
selected, the timer will always disarm the partition, provided the timer function is
enabled. If the option is not selected, the timer will disarm the partition only if it
has armed it itself.
SECOND SET OF OPTIONS (for LED keypad, the LED No. 11 is blinking)
No. LCD LED OPTION
on Do not allow arming during battery trouble.
1
off Allow arming during battery trouble.
on Automatic reset of zone bypassing at midnight (00:00)
2
off Do not reset zone bypassing AUTORESET 1/3
on
Service Mode only available in one partition (access to
service mode in other partitions keypads disabled)
3
off Service Mode available in all partitions.
on Display service message after tamper alarm.
4
off No service message after tamper alarm.
on Keypad trouble alarm on until cleared
5
off Keypad alarm on during trouble only
on Audible tamper alarm in armed mode only
6
off Tamper alarm always audible
on Limit number of alarms from one zone to 3
7
off Alarm will not occur if keypad is alarming
NOTE: Don’t set option 8.