Installation guide
Section 4 - Programming – Service Functions 69
Additional Functions
Extra functions, which were added in the process of developing the functional
features of the CA10, and then the CA10 plus control panels.
FS-126- programming partition control codes (HEX).
Eight event codes are programmed in the following order:
• entry/exit partition 1 (enter control code - partition 1)
• entry/exit partition 2 (enter control code - partition 2)
• entry/exit partition 3 (enter control code - partition 3)
• entry/exit partition 4 (enter control code - partition 4)
• no control code - partition 1
• no control code - partition 2
• no control code - partition 3
• no control code - partition 4
If the "entry/exit" codes are one-digit numbers, they can be automatically extended
by the user number.
FS-127- zones bypassed on no exit from partition 1 (BIT)
FS-128- zones bypassed on no exit from partition 2 (BIT)
FS-129- zones bypassed on no exit from partition 3 (BIT)
FS-130- zones bypassed on no exit from partition 4 (BIT)
The EXIT-BYPASS functions 127 and 130 make it possible to program for each
partition the zones which will be automatically bypassed if, after arming, there is
no violation of the ENTRY/EXIT type zone during the exit delay (after arming the
system, the user has not left the facility and has not violated any detector in the
ENTRY/EXIT type zone).
The programming procedure is identical as for the function FS-8.
FS-131 - programming additional options (BIT)
FIRST SET OF OPTIONS (for LED keypad, the LED No. 12 is blinking)
No. LCD LED OPTION
on service mode disabled
1
off service mode enabled
on DTMF (MST-1) module supported
2
off DTMF (MST-1) module not supported
on pulse dialing ration 1:1,5
3
off pulse dialing ratio 1:2
on global codes
4
off individual codes for each partition
on partition 1 timer priority enabled
5
off partition 1 timer priority disabled
on partition 2 timer priority enabled
6
off partition 2 timer priority disabled
on partition 3 timer priority enabled
7
off partition 3 timer priority disabled
on partition 4 timer priority enabled
8