Installation guide

68 Special Functions
messages. If parameters of such signals change, it will be sufficient to specify new
data.
The programming consists in entering six two-character codes which are suitable
for the given paging system (after a restart, the POLPAGER system parameters
should be entered).
POLPAGER - [118]# [81]#[B1]#[51]#[81]#[00]#[40]#
TELEPAGE - [118]# [2B]#[2E]#[0E]#[14]#[30]#[3A]#
EASYCALL - [118]# [37]#[3D]#[07]#[0B]#[B6]#[C8]#
METRO BIP - [118]# [16]#[1A]#[13]#[17]#[0B]#[0F]#
FS-119 - programming message 1 (HEX)
The function permits programming an alphanumeric message for any paging
system. The programming consists in entering up to 84 message characters (in
two-character pairs), in a convention required by the given system.
Apart from the digits 0 to 9, some systems require additional characters:
A (HEX) =
*
0 - [#]
B (HEX) =
*
1 - [
*
]
C (HEX) =
*
2 - end of message
E (HEX) =
*
4 - pause (required in some systems to separate the pager
number from the message)
D & F (HEX) - same as C.
FS-120 - programming message 2 (HEX)
FS-121 - programming message 3 (HEX)
FS-122 - programming message 4 (HEX)
Note: The functions FS 119 - FS 122 are an alternative to the functions FS 96
- FS 99. Each message can be programmed in two ways (in the HEX mode or
in the POLPAGER receiver convention).
FS-123- counter count-up times
The function allows programming time intervals for the counters 1, 2 and 3, during
which the counters must count up the programmed number of pulses to trigger an
alarm. If the number of violations is less than the preset value, the counters will be
reset after that time. The programming consists in entering three numbers from
between 1 to 255 seconds (each of them should be confirmed with the [#] key),
similarly as in FS-24.
FS-124- keypad address auto-detect
The function enables the keypad addresses to be automatically detected without
changing the other parameters.
FS-125- testing outputs
The function makes it possible to check that all the wiring of control outputs for
signaling devices or other equipment is properly connected. For functional check
of an output, call the function and press the key with number of the output (1-6).
Enabling the output is acknowledged with two short beeps and illumination of the
LED with the output number. The output will be disabled by pressing again the key
with the output number (signaled by one short beep and extinguishing of the LED).
Calling the function will disable all the active outputs (if they have been active),
while quitting the function will reset the same. If the outputs OUT5 and OUT6 are
functioning in the „radio messaging control” mode (FS-5 option 7 of the second
set), the function will not make them available for testing.