Installation guide

Section 4 - Programming – Service Functions 67
start the DLOAD10 program on the computer and select the number of
communication port (COM);
call the service mode in the panel and activate the function FS-112.
Calling the function FS-112 will be signaled by the panel with lighting the
TROUBLE LED. If the panel receives no computer readiness signal within 10
seconds (due to an incorrect computer connecting cable or port number) the
function will be automatically exited.
The waiting for the computer command during an active connection is signaled by
one short beep every 10 seconds. When the connection is broken, the control
panel quits the function and enters the service mode.
Having entered the FS-112 function, the keypad accepts no commands from
keypad - the control panel receives commands from computer. The function
is exited after sending a suitable command by the computer (while exiting the
service mode). It is possible to quit the function by pressing and holding down the
[
*
] key for about 3 seconds.
Programming from the computer with no use of the control panel keypad is
possible after connection of a computer with running DLOAD10 program and
powering up the system (call the function „Local connection with...” or press the
CTRL-1 keys).
FS-113 - event log printout (all events)
The control panel event log can be printed if a printer with RS-232 port is
connected to the control panel. The printout is started by calling the function. No
DTR signal from the printer will terminate the function and an error will be signaled
(two short beeps). Holding down the [
*
] key will stop the printout.
Note: Activation of the "printing on" option is not necessary - it regards
a situation, when the printer is connected permanently.
FS-114 - alarm log printout
It operates in the same way as FS-113, but alarms only are printed.
FS-115 - trouble log printout
It operates in the same way as FS-113, but troubles only are printed.
FS-116 - partition event printout (arming/disarming)
It operates in the same way as FS-113, but only arming and disarming events are
printed.
FS-117 - permissible telephone line loss delay (DEC)
The function defines how many minutes may elapse from the low voltage
condition on the telephone line to the moment the panel reports a trouble. The
programming consists in entering a two-digit number from 00 to 99 minutes. If 00
is programmed, the panel will never report a trouble.
EXAMPLE:
programming a twenty-minute delay
[1][1][7][#] - call the function
[2][0] [#] - program the delay
FS-118 - parameters of pager station signals (HEX)
The function defines parameters of the answer signals generated by automatic
pager station. As different answer signals are used in each system, it is necessary
to specify the signal parameters of the system to which the panel transmits its