66 Special Functions
MASTER code, partition 3 = 3456
MASTER code, partition 4 = 4567.
FS-111 - programming keypad addresses (BIT)
The keypads of CA-10 plus panel have an individual address, which is set with
jumpers. The panel imports this address together with other keypad data (zone
state, depressed keys, anti-tampering) and compares with the address
programmed in the nonvolatile memory for each keypad. If a difference is
detected, a tamper alarm is triggered.
A keypad with incorrect address is not recognized by the control panel. The
addresses are not controlled, when the panel is in the service mode.
The keypad addresses are set by the panel automatically with the service function
FS-124 or when programming the default settings FS-107 (the panel reads out the
jumper setting and saves it in memory). The function FS-111 enables the
addresses to be checked and programmed manually from keypads.
The programming consists in lighting up the LEDs which correspond to the jumper
settings. It is performed in two steps. In the first step, the LEDs 1 to 4 show the
address of partition keypad 1 (CLK1), and the LEDs 5 to 8 - the address of keypad
2 (CLK2). In the second step, the addresses of keypad 3 (CLK3, LEDs 1 to 4) and
keypad 4 (CLK4, LEDs 5 to 8) are set. The settings are confirmed with the [#] key.
The [
*
] key enables you to exit the function.
+KPD Z1 Z2
Partition 1keypad
DCBA
RS -232 (LCD)
123
4
56
78
9
*
0
#
1
2
3
4
5
6
7
8
ALARM
ARMED
TROUBLE
A
B
C
D
2
1
kpd.1
kpd. 2
counter
A
B
C
D
Set keypad
address 1 : 1101_
LCD keypad:
Fig. 14
- Jumper setting and corresponding LEDs during programming.
Notes:
The control panel does not support a keypad in which either all jumpers or
no jumpers are set.
When programming the keypad addresses be particularly careful, as having
programmed wrong addresses will trigger a tamper alarm on quitting the
service mode and loss of the ability to control the panel from the keypad
.
Then it is necessary to enter the service mode by hardware means and read
the new addresses (see chapter “Starting the Control Panel).
The new addresses (as most of the programmed parameters of the panel)
will become valid after exiting the service mode or - when the panel is being
programmed from the computer - after the data are sent.
FS-112 - start of programming through RS-232
The function starts the panel programming through the RS-232 link.
Prior to using the function:
hook up the control panel to the computer using a suitable cable (see
"Connecting a printer or computer"); the length of cable can be from ten to
twenty meters;