Section 4 - Programming – Service Functions 65
The programming consists in entering four characters from 0 to B (twice two
characters), the first character defining the function of TIMER 1, the second -
TIMER 2, the third - TIMER 3, and the fourth - TIMER 4.
The entered characters have the following meaning:
0 - TIMER not used
1 - controls output OUT1
2 - controls output OUT2
3 - controls output OUT3
4 - controls output OUT4
5 - controls output OUT5
6 - controls output OUT6
7 - partition control timer (guard control)
8 - controls partition 1
9 - controls partition 2
A - controls partition 3 (entered by [
*
0])
B - controls partition 4 (entered by [
*
1])
When the timer controls a partition or a output, both times are relevant: timer "on"
and "off". When the guard control function is performed, only the first time
programmed in the functions is used. The hour and minute of „switching on” as
programmed for that timer define the maximum time that may elapse since the
last time the guard code was entered - if it is exceeded, the “no control code”
event will be recorded in the memory, the information will be sent to the monitoring
station, and the “no partition control code” type output will be activated.
EXAMPLE:
programming the function: TIMER1 - controls partition 1, TIMER 2 - controls OUT4
output, TIMER 3 and TIMER 4 - control OUT5 output
[1][0][6] [#] - call the function
[8][4] [#] - program the functions of timers 1 and 2
[5][5] [#] - program the functions of timers 3 and 4
Special Functions
FS-107 - restoration of default settings
Calling this function will restore all the default settings of the control panel
parameters and will automatically program current address of the keypads (and
expander).
The function sets the service code as 12345, but does not change the user
access codes. Description of the settings can be found at the beginning of section
4 (“Programming - Service Functions”).
FS-108 - clearing event log
Calling this function will erase the memory of events.
FS-109 - programming default identification codes
Calling this function will set the codes of control panel and computer, which are
required for the panel to establish communication with the computer. These
settings are used for testing the control panel.
FS-110 - restoring default codes
Calling this function will erase all the user access codes and restore the default
codes:
• service code = 12345
• MASTER code, partition 1 = 1234