Installation guide
64 Functions Programming Dialer
which cannot be reached (when nobody answers the call or the panel
receives the busy signal all the time, etc.).
The programming consists in entering two digits. The first of them refers to the
number of retries, the second - to the number of message queues. Having
programmed these parameters, press the [#] key to exit the function.
FS-101 - programming number of rings before answer (DEC)
The function sets the number of rings after which the CA-10 plus control panel will
answer the call in order to report the alarm system status or to establish
communication with the computer. The programming consists in entering
a number from 00 to 07 and confirming it with the [#] key
Depending on how the answering option bit is set (function FS 5, 8 bit in the
second set of options), the control panel will answer the call immediately after
detecting the programmed number of rings, or on the first ring detected after an
interval lasting less than 5 minutes from detecting the programmed number of
rings ("double call").
Notes:
• Having answered a call in the "single call" mode, the panel will not answer
any more calls for about 5 minutes so as to enable access to other
equipment connected after the panel (e.g. automatic answering system,
fax/modem).
• When the option to establish communication with the control panel by the
computer is disabled, and the call answering is on, the control panel will only
answer the calls when all defined partitions are armed.
Functions programming TIMERS
The CA-6 plus control panel is equipped with four TIMERS, which compare on
the current basis the panel clock with the times set on the TIMERS. If the times are
consistent, the timers perform the functions assigned to them.
FS-102 - programming TIMER 1 (DEC)
The function defines the TIMER 1 ON/OFF hour and minute. The programming
consists in entering four two-digit numbers, the first two denoting the ON time
(hour, minute), and the other two the OFF time (hour, minute).
The timer can only perform either the starting or the stopping function – e.g. if the
timer is to be used for starting only, enter the off time as 99:99.
EXAMPLE:
programming the TIMER 1 - ON 16:30, OFF 06:30
[1][0][2] [#] - call the function
[1][6] [#] - program the on hours
[3][0][#] - program the on minutes
[0][6][#] - program the off hours
[3][0][#] - program the off minutes and exit the function.
FS-103 - programming TIMER 2 (DEC)
FS-104 - programming TIMER 3 (DEC)
FS-105 - programming TIMER 4 (DEC)
FS-106 - programming TIMER functions (HEX)
The function defines how the timers are used. They can control outputs (the