Installation guide
Section 4 - Programming – Service Functions 59
show the programmed code (1 to 4 the first character, 5 to 8 the second character
of the code). The LEDs 9 to 12 show the number of event programmed, according
to the list below:
Number LEDs 9-12 Event
1 {{{ Arming *
2 {{{ Silent arming *
3 {{ Arming with bypass *
4 {{{ Clearing alarm *
5 {{ Disarming *
6 {{ not used
7 { Clock setting *
8 {{{ Zone bypass *
9 {{ Keypad FIRE alarm
10 {{ Keypad PANIC alarm
11 { Keypad auxiliary alarm
12 {{ Keypad tamper alarm
13 { 3 wrong codes alarm
14 { DURESS alarm
15 Internal partition arming
16 {{{{ Internal partition disarming
Notes:
•
The event codes marked * can be extended by the panel with the user
number (see: MONITORING OPTIONS).
•
The "arming with bypass" code is sent when some of the partition zones
were bypassed at the moment of arming.
•
The code numbers 15 and 16 are sent when the partition was armed by the
superior partition user (the corresponding event code, with the number of
that user, is sent as part of handling the superior partition events).
FS-73 - programming partition 1 event assignment to station 1 (BIT)
FS-74 - programming partition 2 event assignment to station 1 (BIT)
FS-75 - programming partition 3 event assignment to station 1 (BIT)
FS-76 - programming partition 4 event assignment to station 1 (BIT)
The functions FS-73 to FS-76 define which events from a given partition will be
reported to the first monitoring station when the mode of reporting to both stations
is activated.
The programming in the LED keypad consists in indicating the events which are to
be reported, by lighting up the corresponding LEDs. In the first stage (LED 12 is
blinking), the LEDs 1 to 8 show directly the event number. In the second stage
(LED 11 is blinking) they show the events 9 to 16. Selection of the events should
be confirmed with the [#] key.
FS-77 - programming partition 1 event assignment to station 2 (BIT)
FS-78 - programming partition 2 event assignment to station 2 (BIT)
FS-79 - programming partition 3 event assignment to station 2 (BIT)
FS-80 - programming partition 4 event assignment to station 2 (BIT)
The functions FS-77 to FS-80 define which partition events will be reported to
the second monitoring station when the mode of reporting to both stations is
activated.