FS-61 - programming zone tamper alarm codes (HEX)
The codes programmed with this function are reported when the control panel
detects violation of the anti-tampering contact in 2EOL/NC and 2EOL/NO zones,
which triggers a tamper alarm.
FS-62 - programming zone trouble codes (HEX)
The codes programmed with this function are reported when the control panel
detects trouble of a detector associated with the zone (too long zone violation
and/or too long zone no-violation time).
FS-63 - programming zone violation codes (HEX)
The function is used for programming the zone violation codes. The zone violation
code is transmitted to the monitoring station in case of:
• violation of an armed delayed zone (of ENTRY/EXIT, INTERIOR DELAY,
DELAY type) when the control panel has started the entry delay countdown,
• violation of an armed counting zone – when the number of violations still
does not trigger an alarm,
• violation of a DAY/NIGHT zone when it is disarmed,
• violation of an armed zone when the zone already signals an alarm -
during the alarm no subsequent alarms are signaled, and the consecutive
detector excitations are recorded in the event log as “zone violation”; when
the alarm signaling is over, each next violation of the detector will trigger an
alarm.
NOTE: A trouble to program the codes of alarms and violations for all the zones
may result in the station being not notified of the alarm. If one of the control
panel zones has no alarm code assigned to it, and it will trigger an alarm, the
excitations of subsequent detectors which occur during the alarm will be saved
in the memory as zone violations, not alarms. If the system comprises any
zones triggering an alarm of which the monitoring station is not notified, it is
necessary to enter the same violation codes for the monitored zones as for the
alarms.
FS-64 - programming zone RESTORE codes (HEX)
The codes programmed with this function are sent after the zone returns to its
normal state (according to the setting of corresponding zone options).
FS-65 - programming zone TAMPER RESTORE codes (HEX)
The codes programmed with this function are sent after the anti-tampering contact
of detector associated with the zones 2EOL/NC and 2EOL/NO returns to its
normal state.
FS-66 - programming zone TROUBLE RESTORE codes (HEX)
The codes programmed with this function will be sent after the trouble ends (i.e.
when the zone is restored to its normal state after too long a violation, or when a
violation occurs after "too long time of no violation ").
FS-67 - programming zone event assignment to station 1 (BIT)
FS-68 - programming zone event assignment to station 2 (BIT)
The functions define, which zone events are to be sent to station 1, and which to
station 2 (monitoring set for both stations in FS-47).
The programming in the LED keypad consists in lighting up the event indicating
LEDs and confirming the selection with the [#] key.