Installation guide
56 Functions Programming Identifiers
FS-58 - programming partition 4 events identifier for station 2 (HEX)
FS-59 - programming system events identifier for station 2 (HEX)
EXAMPLE:
programming the zone event identifier for the station 1 = A243
[4][8] [#] - call the function
[
*
0][2] [#] - enter the first two characters of identifier
[4][3] [#] - enter the next two characters of identifier and confirm them - exit the function
Functions Programming Zone Event Codes
The zone event codes are programmed in the functions FS-61 to FS-66, and also
FS-134 and FS-135. Each of them is used for programming a code of one event
for each of the 16 zones of the panel.
The zone event codes may be either single or double character.
For the data formats 4/1 and 3/1 (and also when using the mode with code
extension by zone number, see FS-47 "Monitoring options"), one of the characters
must be 0.
Programming 00 will result in skipping the event when the events are being
reported to the station.
The programming consists in entering two characters (from 0 to F) for each zone
and confirming them.
When programming in the LED keypad, the LEDs show value of the character
entered (from 1 to 4 - the first character, and from 5 to 8 - the second character of
the code) and number of the zone for which the code is programmed (LEDs 9 to
12). After confirmation of the last zone code, the control panel exits the function.
FS-60 - programming zone alarm codes (HEX)
The codes programmed with this function are reported when the control panel
detects violation of the zone which triggers an alarm. 16 zones of the panel are
successively programmed.
EXAMPLE:
programming the alarm codes for the zones 1 to 7 (codes from 41to 47) and 9 to 16
(codes from 48 to 4F), the zone 8 not being an alarm one.
[6][0] [#] - call the function
[4][1] [#] - program the code for zone 1
[4][2] [#] - program the code for zone 2
[4][3] [#] - program the code for zone 3
[4][4] [#] - program the code for zone 4
[4][5] [#] - program the code for zone 5
[4][6] [#] - program the code for zone 6
[4][7] [#] - program the code for zone 7
[0][0] [#] - program the code for zone 8 (no event for zone 8)
[4][8] [#] - program the code for zone 9
[4][9] [#] - program the code for zone 10
[4][
*
0] [#] - program the code for zone 11 (code 4A)
[4][
*
1] [#] - program the code for zone 12 (code 4B)
[4][
*
2] [#] - program the code for zone 13 (code 4C)
[4][
*
3] [#] - program the code for zone 14 (code 4D)
[4][
*
4] [#] - program the code for zone 15 (code 4E)
[4][
*
5] [#] - program the code for zone 16 (code 4F), quit the function.