Installation guide
Section 4 - Programming – Service Functions 55
• The options 5 and 6 are only meaningful when double-character codes are
reported (with 4/2 or 3/2 format). If this is the case, single-character event
codes are programmed, and the panel, with the extension option on, will add
the zone number or the user number, respectively, as the second character.
The codes programmed as double-character ones will be sent in their
programmed form. This solution has been adopted to facilitate programming
of the event codes. As a result, programming e.g. the „zone alarm” codes
(FS-60) for all the zones from which such a code is to be sent, it is sufficient
to give just one (the same) character.
Functions Programming Identifiers
The functions FS-48 to FS-59 are used to program identifiers to be sent to the
monitoring stations. Depending on the needs, the control panel can send to the
station quite detailed data on the events occurring in the system, or just the basic
ones. With two-character codes, it is possible to send information on 225 events.
In order to circumvent restrictions caused by the transmission formats, some
solutions have been applied in the CA10 plus control panel, which consist in
grouping the events (zone events, partition 1 events, etc.) and assigning a
separate identifier to each group.
In case of a small amount of information being sent (less than 225 different
events), all the identifiers for the particular station are to be programmed
identically, and the event sorting mode is to be disabled in monitoring options.
The functions programming identifiers function so that the LEDs 1 to 8 shown two
consecutive characters (see the HEX function description) which can be changed
by entering new ones. When programming the first two characters, the LED 12 is
blinking, when programming the oter two - the LED 11 is blinking.
For the data formats 3/1 and 3/2, the last character should be 0 - the control
panel will send characters from 1 to F, 0 not being sent.
NOTE: If the monitoring station requires an identifier containing the digit zero,
enter the character “A” instead of zero (e.g. the identifier “1203” should be
entered as “12A3”).
FS-48 - programming zone events identifier for station 1 (HEX)
FS-49 - programming partition 1 events identifier for station 1 (HEX)
FS-50 - programming partition 2 events identifier for station 1 (HEX)
FS-51 - programming partition 3 events identifier for station 1 (HEX)
FS-52 - programming partition 4 events identifier for station 1 (HEX)
FS-53 - programming system events identifier for station 1 (HEX)
FS-54 - programming zone events identifier for station 2 (HEX)
FS-55 - programming partition 1 events identifier for station 2 (HEX)
FS-56 - programming partition 2 events identifier for station 2 (HEX)
FS-57 - programming partition 3 events identifier for station 2 (HEX)