Installation guide
Section 4 - Programming – Service Functions 53
FS-38 - programming list of zones OUT4 (BIT)
The function programs the list of zones associated with the OUT4 output. The
programming procedure is same as for the FS-32.
FS-39 - programming OUT5 output
The function defines the basic parameters associated with the OUT5 output. The
programming procedure is same as for the FS-31.
FS-40 - programming list of zones OUT5 (BIT)
The function programs the list of zones associated with the OUT5 output. The
programming procedure is same as for the FS-32.
FS-41 - programming OUT6 output
The function defines the basic parameters associated with the OUT6 output. The
programming procedure is same as for the FS-31.
FS-42 - programming list of zones OUT6 (BIT)
The function programs the list of zones associated with the OUT6 output. The
programming procedure is same as for the FS-32.
Functions programming parameters of transmission to monitoring stations
FS-43 - programming station 1 number 1 (HEX)
FS-44 - programming station 2 number (HEX)
Numbers of up to 16 characters (digits and control codes) are programmed in the
same way as the modem telephone number (FS-4).
FS-45 - programming station 1 format (HEX)
FS-46 - programming station 2 format (HEX)
The functions define the standard of event transmission to the monitoring stations.
They are programmed by entering a double-character format number and
confirming it with the [#] key.
TRANSMISSION FORMATS:
00 - Silent Knight, Ademco slow (1400Hz/10Bps)
01 - Sescoa, Franklin, DCI, Vertex (2300Hz/20Bps)
02 - Silent Knight fast (1400Hz/20Bps)
03 - Radionics 1400Hz
04 - Radionics 2300Hz
05 - Radionics with parity 1400Hz
06 - Radionics with parity 2300Hz
07 - Ademco Express
08 - Silent Knight, Ademco slow, extended
09 - Sescoa, Franklin, DCI, Vertex, extended
0A - Silent Knight fast, extended
0B - Radionics 1400Hz, extended
0C - Radionics 2300Hz, extended
0D Telim with entry tone – without signalling test of connection
8D - Telim without entry tone – with full signalling test of connection
0E Contact ID selected codes
0F Contact ID all codes