Installation guide
50 Functions Programming Output Parameters
Functions Programming Output Parameters
FS-31 - programming OUT1 output
The function makes it possible to define basic parameters regarding the OUT1
output:
• output type (determines in which conditions the output will be activated),
• output cut-off time,
• operation options (e.g., "polarity").
In the LED keypad, after selecting the function, the LEDs 1 to 8 show the
respective parameter setting, while the LEDs 9 to 12 show which parameter is
being programmed.
The first parameter defines the output type (the LED 12 is blinking). The
programming consists in entering a two-digit number (identically as in the DEC
functions) and confirming it with the [#] key.
Each of the outputs can be assigned any type from the following list:
00 - NOT USED
01 - BURGLARY ALARM
02 - FIRE/BURGLARY ALARM
03 - FIRE ALARM
04 - KEYPAD ALARM
05 - KEYPAD FIRE ALARM
06 - KEYPAD PANIC ALARM
07 - KEYPAD AUX. ALARM
08 - KEYPAD TAMPER ALARM
09 - DAY/NIGHT + COUNTING
10 - DURESS ALARM
11 - CHIME
12 - SWITCH MONO
13 - SWITCH BI (ON/OFF)
14 - ARM STATUS
15 - SILENT ARM STATUS
16 - EXIT DELAY WARNING
17 - ENTRY DELAY WARNING
18 - TEL. USAGE STATUS
19 - GROUND START
20 - MONITORING ACKNOWLEDGEMENT
21 - BYPASS STATUS
22 - READY STATUS
23 - ZONE VIOLATION
24 - TELEPHONE LINE FAULT
25 - 230V AC LOSS INDICATOR
26 - BATTERY TROUBLE INDICATOR
27 - POWER SUPPLY
28 - FIRE POWER SUPPLY
29 - RESET POWER SUPPLY