Installation guide
Section 4 - Programming – Service Functions 47
03 - EOL detector (one-parameter - default value)
04 - 2EOL/NC detector (two-parameter – NC detector)
05 - 2EOL/NO detector (two-parameter–NO detector)
During the programming, the control panel will display the current parameter
setting (in binary form) on the LEDs 1 to 8. The LEDs 9 to 12 indicate the zone for
which the detector type is being programmed.
EXAMPLE:
programming the EOL type zones 1 do 6, NC type zones 7 to 8, the other zones (13 to
16) not used
[2][5] [#] - call the function
[0][3] [#] - detector type for the first zone (LEDs 9-12 = 0001)
[0][3] [#] - detector type for the second zone (LEDs 9-12 = 0010)
[0][3] [#] - detector type for the third zone (LEDs 9-12 = 0011)
[0][3] [#] - detector type for the fourth zone (LEDs 9-12 = 0100)
[0][3] [#] - detector type for the fifth zone (LEDs 9-12 = 0101)
[0][3] [#] - detector type for the sixth zone (LEDs 9-12 = 0110)
[0][1] [#] - detector type for the seventh zone (LEDs 9-12 = 0111)
[0][1] [#] - detector type for the eighth zone (LEDs 9-12 = 1000)
[0][1] [#] - detector type for the ninth zone (LEDs 9-12 = 1001)
[0][1] [#] - detector type for the tenth zone (LEDs 9-12 = 1010)
[0][1] [#] - detector type for the eleventh zone (LEDs 9-12 = 1011)
[0][1] [#] - detector type for the twelfth zone (LEDs 9-12 = 1100)
[0][0] [#] - no detector on zone 13 (LEDs 9-12 = 1101)
[0][0] [#] - no detector on zone 14 (LEDs 9-12 = 1110)
[0][0] [#] - no detector on zone 15 (LEDs 9-12 = 1111)
[0][0] [#] - no detector on zone 16 (LEDs 9-12 = 0000)
FS-26 - programming zone reaction type (DEC)
The control panel reaction to a zone violation depends on the function assigned to
the given zone (e.g., the reaction will be different in the case of a 24 h fire type
zone violation, and in the case of an arming zone violation).
The programming consists in entering an appropriate two-digit number for each
zone to determine its function (reaction type). Each of the CA-10 plus zones can
perform one of the 21 functions:
00- ENTRY/EXIT
01- DELAY
02- INTERIOR DELAY
03- INSTANT
04- DAY/NIGHT
05- COUNTING L1
06- COUNTING L2
07- COUNTING L3
08- 24H AUDIBLE
09- 24H AUXILIARY
10- 24H SILENT
11- 24H FIRE
12- ARMING
13- SILENT ARMING
14- DISARMING
15- NO ALARM ACTION
16- ARMING/DISARMING
17- DELAY AUDIBLE
18- AUTOMATIC BYPASS ARMING
19- PERIMETER
20- ENTRY/EXIT-FINAL