Installation guide

44 Functions Programming Assignment
must be separately programmed in the keypad itself (see:
¤
Installation Guide
for LCD Keypad;
¤
Keypad Service Functions;
¤
Settings;
¤
Function GO TO).
FIRST SET OF OPTIONS (for LED keypad, the LED No. 12 is blinking)
No. LCD LED Option
ON
function GO TO Partition
2
disabled
1
OFF
function GO TO Partition
2
enabled
ON
function GO TO Partition
3
disabled
2
OFF
function GO TO Partition
3
enabled
ON
function GO TO Partition
4
disabled
3
OFF
function GO TO Partition
4
enabled
ON
quick arming [0][#] disabled
4
OFF
quick arming [0][#] enabled
ON
3 wrong codes alarm disabled
5
OFF
3 wrong codes alarm enabled
ON
PANIC alarm disabled
6
OFF
keypad PANIC alarm enabled
ON
AUX alarm disabled
7
OFF
keypad AUX alarm enabled
ON
FIRE alarm disabled
8
OFF
keypad FIRE alarm enabled
SECOND SET OF OPTIONS (for LED keypad, the LED No. 11 is blinking)
No. NR LCD LED Option
1 ON
2 OFF
keypad alarm signal on until cleared
1 9
1 OFF
2 ON
alarm signal for the global alarm time
2 A
1 OFF
2 OFF
no keypad alarm signal
ON
DAY/NIGHT or COUNTING zone violation signaled in keypad (5
long beeps)
3 B
OFF
no DAY/NIGHT or COUNTING zone violation signaled in keypad
ON
CHIME signal on (five short beeps)
4 C
OFF
CHIME signal off
ON
trouble signal on (two short beeps every 3 seconds)
5 D
OFF
trouble signal in keypad off
ON
EXIT DELAY signal on (one long beep every three seconds)
6 E
OFF
EXIT DELAY signal off
ON
ENTRY DELAY signal on (one sort beep every three seconds)
7 F
OFF
ENTRY DELAY signal off
ON
key pressed signal on
8 G
OFF
no key pressed signal