Installation guide

Section 4 - Programming – Service Functions 43
FS-11 - programming partition 4 zones (BIT)
The functions FS-8 to FS-11 are used to divide the alarm system into partitions.
Full description of the possibilities to divide the panel into partitions -see section
TECHNICAL DESCRIPTION OF THE CONTROL PANEL – PARTITIONS.
Programming in the LED keypad consists in lighting up the LEDs which indicate
the zones that should be assigned to the given partition. It is a two-stage process.
In the first stage the zones 1 to 8 are programmed (LED 12 is blinking). In the
second stage - the zones 9 to 16 (LED 11 is blinking), the LED 1 indicating zone
9, LED 2 - zone 10 etc. Use the [#] key to proceed to the next stage, and then to
exit the function.
In the LCD keypad, the zones are selected by entering their number (1,2...9, the
tenth as „A” – [
*
][0], up to the sixteenth „G” – [
*
][6]), or by means of the arrow
keys. The zone not belonging to a partition is indicated by a dot. Pressing the ×
key displays the name of the currently selected zone.
FS-12 - programming zones displayed in partition 1 keypad (BIT)
FS-13 - programming zones displayed in partition 2 keypad (BIT)
FS-14 - programming zones displayed in partition 3 keypad (BIT)
FS-15 - programming zones displayed in partition 4 keypad (BIT)
The control panel makes it possible to determine any zones which will be
displayed in the actual LED keypad. Twelve out of sixteen zones are selected.
The control panel displays the indicated zones arranged from the lowest number
zone to the highest number zone, e.g. if the zone 1 has not been selected to be
displayed, the first LED will show state of the zone 2. If less than 12 zones are
selected, some of the keypad LEDs will be not used.
The functions FS 12 – FS-15 define the zones displayed in the LED keypad
controlled, respectively, from the outputs CLK1 (zone 1) – CLK4 (zone 4)
The programming is similar to that in FS-8 (partition zones).
FS-16 - programming bypassed zones in partition 1 (BIT)
FS-17 - programming bypassed zones in partition 2 (BIT)
FS-18 - programming bypassed zones in partition 3 (BIT)
FS-19 - programming bypassed zones in partition 4 (BIT)
The functions 16 to 19 (AUTO-BYPASS) apply to the zones which are
automatically bypassed after silent or loud arming with the authority level 7 code
(partial arming). The programming is similar to that in FS-8.
NOTE: The zones to be bypassed at no exit from the partition are programmed
with the service functions FS 127
÷
130 (EXIT-BYPASS).
FS-20 - programming partition 1 options (BIT)
In order to increase flexibility of the system, some functions of the keypads are
optional. They are performed by the CA10 plus control panel only in partitions,
where they are not disabled. Two sets of options are programmed for each
partition. The first set (LED 12 blinking) defines availability of the functions
activated by holding down one key. The other set (LED 11 blinking) defines which
audible signals are generated by the partition keypad.
The options selected for each set should be confirmed with the [#] key.
NOTE: The options 1,2 & 3 of the first set in the service functions FS-20 to FS-
23 refer to the LED keypads and are irrelevant, when LCD keypads only are
installed in the system. To enable GOTO function for the LCD keypads, settings