Installation guide
Section 4 - Programming – Service Functions 41
SECOND SET OF OPTIONS (for LED keypad, the LED No. 11 is blinking)
No. No. LCD LED Option
ON
DOWNLOADING activation from outside
enabled
1
9
OFF
DOWNLOADING activation from outside
disabled
ON
TONE
dialing
2 A
OFF
PULSE
dialing
ON
double
playback of alarm message from synthesizer
3 B
OFF
single
playback of alarm message
ON
GROUND-START signal
generated
before dialing (special tel. line
service)
4 C
OFF
GROUND-START signal
blocked
ON
no dial tone test
before dialing the number
5 D
OFF
dialer waits for dial tone before dialing the number
ON
no answer test
(synthesizer message emitted 15 seconds after
dialing the number)
6 E
OFF
call answer test activated
(the dialer will send the message after
detecting the call answer)
ON
OUT5, OUT6 outputs control the radio messaging
7 F
OFF
OUT5, OUT6 outputs perform their assigned functions
ON
double call
to answer
8 G
OFF
single call
to answer
THIRD SET OF OPTIONS (for LED keypad, the LED Nos. 11, 12 are blinking)
No. No. LCD LED Option
ON
service mode unavailable if any partition is armed
1 H
OFF
service mode always available
ON
communication with the computer unavailable if any partition is armed
2 I
OFF
communication with the computer always available
ON
alarm if zones are violated after the exit delay elapses
3 J
OFF
control panel does not alarm if zones in a partition are violated after the exit
delay elapses
ON
fire alarm signaled only in partition where it was activated
4 K
OFF
fire alarm signaled in all partitions
ON
keypad alarm (PANIC, AUX, TAMPER) signaled only in partition where it
was activated
5 L
OFF
keypad alarm signaled in all partitions
ON
in case of problems with transmission to the station monitoring suspended
until occurrence of a new event
6 M
OFF
monitoring suspended for 30 min
ON
OUT5 and OUT6 outputs work in „UA” format
7 N
OFF
OUT5 and OUT6 outputs work in PC16OUT format (options 7, 8
deactivated)
ON
OUT5 and OUT6 outputs work in „LV&BY” format
8 O
OFF
OUT5 and OUT6 outputs work in PC16OUT format (options 7, 8
deactivated)
Note: Options 7 and 8 of the third set are only relevant with activated option 7
of the second set – „outputs OUT5, OUT6 control NOKTON radio messaging”.
The „UA” and „LV” data formats are used by foreign users of the control panels
CA-10 and CA-10 plus.