Installation guide
Section 4 - Programming – Service Functions 39
Programming of this code in the LED keypad consists in entering three pairs of
hexadecimal characters (digits from 0 to 9 and characters A, B, C, D, E, F - see
the table of codes). The LEDs will first display previous settings, and, after the
change - the values of characters entered (binary, the first character - LEDs 1 to 4,
the second - LEDs 5 to 8, number of pair of programmed characters - LEDs 9-12).
Having entered the last pair of characters, the panel automatically exits the
function.
EXAMPLE (for the LED keypad):
programming the identifier 23C4D5
[2] [#] - call the required function.
[2][3] [#] - enter the two first characters
[
*
2][4] [#] - enter the two next characters
[
*
3][5] [#] - enter the two last characters; after acknowledging them the panel will automatically exit
the function
FS-4 - programming computer telephone number (HEX)
The computer telephone number is necessary so that the control panel can call
the computer. The communication can be initiated from the control panel keypad
(user function “0”), or from the computer. The panel, after the handshake, will
hang up and call the computer back. Thus it is impossible to force programming
from any computer, but from the authorized service.
If the computer telephone number is not programmed, the computer initiated
communication can be established in a simplified way - the control panel
will not hang up and call back.
The length of a telephone number can be up to sixteen digits and special
characters. The special characters are used to control the dialing process. In the
LED keypad it is programmed by entering the consecutive digits and characters in
pairs. Each pair is to be confirmed by the [#] key (see the example below). The
LEDs 9,10,11,12 show (in binary form) which pair of characters is being
programmed, and the LEDs 1 to 4 and 5 to 8 show (also in binary form) the values
of programmed digits.
The following codes has been assigned to the functions mentioned below:
A(
HEX
) - control character..............................................(combination [
*
][0])
B(
HEX
) - switch to pulse dialing .....................................(combination [
*
][1])
C(
HEX
) - switch to tone dialing.......................................(combination [
*
][2])
D(
HEX
) - wait for dialing tone .........................................(combination [
*
][3])
E(
HEX
) - short pause (3 seconds).................................. (combination [
*
][4])
F(
HEX
) - long pause (10 seconds).................................(combination [
*
][5])
¾(
HEX
) - signal ¾ in DTMF system .................................(combination A[0])
#(
HEX
) - signal # in DTMF system..................................(combination A[1])
a(
HEX
) - signal a in DTMF system..................................(combination A[2])
b(
HEX
) - signal b in DTMF system..................................(combination A[3])
c(
HEX
) - signal c in DTMF system..................................(combination A[4])
d(
HEX
) - signal d in DTMF system..................................(combination A[5])
Notes:
• Do not program the control characters B, C and D before the telephone
number (these are set in the FS5 options).
• In case of the busy signal, the waiting for dial tone (code D) does
not decrease the counter of queues and retries (e.g. when the panel
is connected to an extension line and the outside line is busy, the panel