Installation guide
Section 4 - Programming – Service Functions 35
• keypad alarm duration - 60 seconds,
• counting times of counters - 30 seconds; counter values - 0,
• all options deactivated (telephone messaging, monitoring, telephone
answering, etc.),
• all data related to monitoring and telephone messaging erased,
• pager station signal parameters in accordance with the POLPAGER system.
All the control panel parameters can be programmed from the keypad, using the
service functions. It is also possible to program the control panel by means of a
computer (in the local mode - through RS-232, or remotely - through the modem).
Service Mode
Control panel programming is possible after activating the service mode. It can
be activated when the control panel is not armed and signals no alarm. The
activation consists in entering the service code (default=12345), confirmed by the [#]
key. After entering the service mode, the LEDs ALARM and PARTITION (ARMED for
the LED keypad) are alternately blinking and a short beep is generated every 3
seconds. The other partitions function normally, alarms being only signaled in the
keypads and reported to the monitoring station. No keypad tamper conditions or
addresses are checked in the service mode. The service mode is on until
deactivated by the service function (FS-0). It can also be exited with a computer
command from the DLOAD program.
Programming with the LED Keypad
When in the service mode, the control panel waits until the function number is
entered and confirmed with the [#] key. After activation of the function the TROUBLE
LED is on, while the others show programmed parameters.
The way of programming and data display in the LED keypad depends on the type of
data entered with the service function. The panel programming is based on three
types of functions: bit (BIT), decimal (DEC) and hexadecimal (HEX).
BIT Functions
The bit functions are used to program two-state parameters: YES and NO (e.g.
the functions of zone assignment to partition, options). During programming with
a bit function, the LEDs 1 to 8 show the current setting of particular parameters
(diode on - YES, off - NO). Pressing the keys [1] to [8] changes the state of the
corresponding diode. The state of 8 parameters is confirmed with the [#] key. If
the programming function includes more parameters, the control panel will signal
with two short beeps acceptance of the first eight parameters and the LEDs 1 to 8
will display the state of the next group of eight. When all the parameters have
been programmed, the control panel will signal exiting the function with four short
a one long beeps.
The LEDs 9 to 12 of the control panel indicate which portion of data (set of
options) is currently programmed.
The [
*
] key makes it possible to quit the function at any time without saving the
changes in currently displayed data.
DEC Functions
These functions are used for programming data in the form of a few digits (for
example, the test transmission time - 4 digits, individual entry delay time of zones -
16 x 2 digits). When running the function program, the LEDs 1-4 show the first
digit (binary), LEDs 5-8 - the second digit, while the LEDs 9-12 display the counter