Installation guide
34 Installation Guide CA-10 plus SATEL
• “connection interrupted” – the control panel stopped answering the
computer signals.
Note: If the control panel answers the call but fails to establish communication
and disconnects, while the “double call” option is deactivated, it will be
answering no calls for the next 5 minutes.
Guard Control Function
The functioning of the guard control function consists in automatically checking that
the, so-called, guard code is entered on the keypad with a preset frequency. The
entry of the code is saved in the log event, and so is the trouble to enter the code
after a preset period of time, which can be signaled on an output which has the
proper function. These events can be reported to the monitoring station.
To activate the function you must:
• program the guard code - in the user function 2 (creating new user) a code
with authority level 5 (instead of the guard code, the user function 7 can also
be used - activation of the „switch MONO" output)
• set a suitable timer to perform the „partition monitoring” function (FS-106)
• program the timer control time (functions FS-102÷105, depending on the
partition).
PROGRAMMING - SERVICE FUNCTIONS
Design and program flexibility of the CA-10 plus control panel give the installer a full
freedom of choice in defining the alarm system functions and operating mode.
Additionally, they allow some extra functions to be assigned to the panel (for
example, control of lighting , locks, cameras).
Control panel configuration after reset (with FS 107 function):
• one partition including all the available zones (Z1 to Z10),
• zone 1 (Z1) - ENTRY/EXIT, EOL (one-parameter),
• zones 2 to 8 (Z2 ... Z8), 9, 10 (Z1 & Z2 in partition 1 keypad) - instant, EOL,
• zones 11 to 16 - not used,
• sensitivity of all zones – 0.48 sec.,
• PRIORITY option activated for all zones - see: FS 27, option no. 1,
• other zone options deactivated, detector operation testing disabled,
• output OUT1 - alarm signaling (BURGLARY type, operation time = 1 min.,
polarity +12V, assigned to all zones),
• output OUT2 - visual signaling device (BURGLARY type, operation time equal
to global time, polarity +12V, assigned to all zones),
• output OUT3 - detectors power supply,
• output OUT4 – not used,
• output OUT5 - READY status (for all zones),
• output OUT6 - telephone messaging status (OUT5 & OUT6 output functions
are connected with testing the panel during production process),
• partition 1 keypad displays all zones available, no automatic zone bypasses, all
functions available, disabled audible trouble signaling only,
• exit delay - 60 seconds,
• exit delay - 30 seconds,