Installation guide

Section 2 - Installation of the Control Panel 29
Note: If LCD keypads are installed in the alarm system, call the FS-124 service
function in each LCD keypad. When activated from the LCD keypad, this
function automatically performs additional configuring operations and its
activation in each LCD keypad is necessary for proper operation of the
system.
The FS-111 service function enables you to set the keypad addresses on your own.
After calling the FS-124 function, it is advisable to check in the FS-111 whether the
addresses have been properly read out – a mismatch between the address read out
with the FS-124 function and the actually set addresses will mean incorrect
connection of the keypads. The expander address should be programmed as the
address of consecutive keypads:
second, third and fourth – if the expander is connected to CLK2
third and fourth – if the expander is connected to CLK3
fourth – if the expander is connected to CLK4
Do not change the addresses with the FS-111 function, unless they have not
been entered from LCD keypads using the FS-124 function.
The user can also program the address himself, by means of the service function FS
111. To make sure that all the settings are in accordance with the default values, you
can perform the service functions FS-107, FS-108 and FS-110.
Having completed the procedure, exit the service mode using the function FS-0 and
activate the service mode again - this time from the keypad - by entering the default
access code [1][2][3][4][5] confirmed with the [#] key.
If the control panel has re-entered the service mode, it means that its functioning is
correct and that you may proceed with further installation of the system (connection
of sensors, signaling devices, establishing communication with a computer, if
required) and programming of all necessary parameters.
If the described procedure is unsuccessful, the option of hardware access to the
service mode must have been disabled in the control panel by software means. If
this is the case, it is necessary to carry out another procedure which would enable
the control panel and restore the default settings - see description of the service
function FS-131.
If signaling devices are triggered upon power-up, starting the control panel may
prove impossible because of the loading level which exceeds the power supply
capacity. If this is the case, the system must be started with signaling devices
disconnected.
Programming the control panel from the computer via the RS-232 port should be
initiated by calling the service mode and the FS-112 communication function in the
control panel. Provision is also made for starting communication without calling the
function FS-112 - which is convenient if the control panel is already installed on the
site and there is no keypad in the vicinity. Detailed description of step-by-step
procedures is available in prompts to the DLOAD program, after selecting the „Local
connection with...” command (Alt-C).
ACTIVATING SELECTED FUNCTIONS
Performance of some functions of the control panel requires that a few to more than
a dozen parameters be programmed simultaneously. This section contains detailed
information on how to program such functions as: telephone messaging, monitoring
and downloading.