Installation guide

Section 1 - Description of the Control Panel 9
7 - KEYPAD AUX. ALARM
- the output starts on triggering the alarm by the user with
the ALARM AUX function. The output operation can be limited to the alarms from
specified partitions. The output can remain active for a specified time (from 01 to 99
seconds or from 01 to 99 minutes) or until the alarm is cleared by the user. During
operation, it can every second change its state (pulsate).
8 - KEYPAD TAMPER ALARM
- the output starts on detecting violation of the tamper
contact or a change of the keypad address, and also after 3 wrong codes. The
output operation can be limited to the alarms from specified partitions. The output
can remain active for a specified time (from 01 to 99 seconds or from 01 to 99
minutes) or until the alarm is cleared by the user. During operation, it can every
second change its state (pulsate).
9 - DAY/NIGHT + COUNTING
- the output starts on detecting violation of disarmed
DAY/NIGHT zone or violations of COUNTING zones, which trigger no alarm.
Operation of the output can be restricted to a specified “list of outputs” or particular
partitions (identically as for the
01
output type). Indication of any other zones than
those tested by this output type is irrelevant - they will give no violation signal. The
output can remain active for a specified time (from 01 to 99 seconds or from 01 to
99 minutes) or until the alarm is cleared by the user. During operation, it can every
second change its state (pulsate).
10 - DURESS alarm
- the output starts on using an access code with authority level 4
(DURESS) to disarm the system or to signal an alarm. This code is used to trigger
a special "disarm under duress" alarm. Operation of the output can be restricted to
alarms from particular partitions. The output can remain active for a specified time
(from 01 to 99 seconds or from 01 to 99 minutes) or until the alarm is cleared by the
user. During operation, it can every second change its state (pulsate).
11 - CHIME
- the output starts on violating the disarmed zones for which the “chime” option
has been activated. Operation of the output can be restricted to the indicated "list of
zones" or to specified partitions (identically as for the
01
output type). The output
can remain active for a specified time (from 01 to 99 seconds or from 01 to 99
minutes) or until the alarm is cleared by the user. The output signals violations
irrespective of the chime lock setting in keypad (the lock is activated with the
function 8, called by holding down the key).
12 - SWITCH MONO
- the output is activated by calling the user function 7
([CODE][*][7])
or using a code with authority level 5
([CODE][#]). Operation of the output can be
restricted to specified partitions. The output can remain active for a time from 01 to
99 seconds or from 01 to 99 minutes.
13 - SWITCH BI (ON/OFF
) - the output changes its state when the user function 8 is
called or a code with authority level 6 is used. Operation of the output can be
restricted to specified partitions.
14 - ARM STATUS
- the output is active in the armed mode. Operation of the output can be
restricted by indicating a „list of zones” or specific partitions. Unless zones and
partitions are indicated, the output is active when any partition (zone) is armed.
15 - SILENT ARM STATUS
- the output is active in the silent armed mode. Operation of
the output can be restricted by indicating a „list of zones” or specific partitions.
16 - EXIT DELAY WARNING
- the output is active during the „exit delay” countdown by
the control panel. Operation of the output can be limited to indicating the „exit delay
for specified partitions.
17 - ENTRY DELAY WARNING
- the output is active during the „entry delay” countdown.
Operation of the output can be limited to indicating the „entry delay” for specified
partitions.
18 - TEL. USAGE STATUS
- the output is active when the control panel is on the
telephone line.
19 - GROUND START
- the output activated by the control panel to generate the
GROUND START pulse (a 2 sec. signal occurring before the control panel "lifts the
handset", required by a specific type of telephone exchanges).
20 - MONITORING CONFIRMATION
- the output activated for 3 seconds by the control
panel, after correct termination of the monitoring session.