Specifications
Installation
40
10" Modero Widescreen Touch Panels
Verify that the terminal end of the power cable is not connected to a power source before
plugging in the 2-pin power connector.
The USB connectors can be from either a USB extension cable, or a wireless USB RF
transmitter.
4. Test the incoming wiring by connecting the panel connections to their terminal locations and
applying power. Verify that the panel is receiving power and functioning properly to prevent
repetition of the installation.
5. Disconnect the terminal end of the power cable from the connected power supply.
6. Carefully slide the main NXD-CV10 unit (B in FIG. 39) into the conduit box, so that all Mounting
Tabs lie flush against the conduit box (C in FIG. 39).
7. Insert and secure four #4-40 Mounting Screws (included) into their corresponding holes located
along the sides of the NXD.
8. Place the Faceplate/Trim Ring assembly (A in FIG. 39) back onto the main NXD unit
(B in FIG. 39). Make sure to align the Microphone, Light, and PIR Motion sensor locations to their
respective openings on the front faceplate/bezel.
9. Reconnect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their
respective locations (outside the conduit box) on either the NXA-AVB/ETHERNET Breakout Box,
Ethernet port, or NetLinx Master.
10. Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.
FIG. 39 NXD-CV10 panel installation into a CB-TP10 (pre-wall construction)
B - Main NXD unit consists of
C - Optional CB-TP10
#4-40 Mounting Screws
(four - included)
secure the NXD to
Stud
the touch panel and back box housing
conduit/wallbox
A - Faceplate/Trim Ring
default Faceplate assembly comes with buttons
the Conduit Box
Mounting Tab
Don’t disconnect the connectors from the touch panel. The unit must be installed with
the attached connectors before being inserted into the conduit box.