17. OFFSET MEASUREMENT
2. Select "Offset" in <Menu> to display .
3. Select "Occupy setup" to display <Occupy
setup>. Enter data for the instrument station and
press [OK] to move to Backsight setup.
C"14.1 Entering Instrument Station Data"
4. Set the azimuth angle for the backsight station.
Press [OK] to return to <Offset>.
C"14.2 Azimuth Angle Setting"
5. Select “OffsetDIST”.
Input the following items.
(1) Direction of the offset point.
(2) Horizontal distance from the target point to
the offset point.
Direction of offset point
: On the left of the target point.
: On the right of the target point.
: Closer than the target point.
: Beyond the target point.